Details of the Researcher

PHOTO

Yohei Inaba
Section
Graduate School of Medicine
Job title
Senior Assistant Professor
Degree
  • 博士(保健学)(東北大学)

Professional Memberships 6

  • 日本IVR学会

  • JAPAN SOCIETY OF MEDICAL PHYSICS

  • 日本災害医学会

  • Japanese Society for Megnetic Resonance in Medicine

  • Japanese Society of Radiation Safety Management

  • Japanese Society of Radiological Technology

︎Show all ︎Show first 5

Research Interests 10

  • 医学物理

  • 災害放射線医学

  • 災害医療

  • 放射線防護

  • 放射線計測

  • MRI

  • IVR

  • ESR

  • フリーラジカル

  • バイオドジメトリ

Research Areas 2

  • Life sciences / Radiology /

  • Life sciences / Medical equipment testing /

Awards 7

  1. Top 10 Cited Articles in 2022–2023

    2024/03 Tomography Radiation Eye Dose for Physicians in CT Fluoroscopy-Guided Biopsy

  2. Most Citation Award

    2023/04 Radiological Physics and Technology

  3. 優秀プレゼンテーション賞

    2022/11 第4回日本保健物理学会・日本放射線安全管理学会合同大会

  4. 一般演題優秀賞

    2020/10 第59回日本消化器がん検診学会総会

  5. 学術奨励賞

    2019/10 公益社団法人日本放射線技術学会東北支部

  6. Featured Abstract賞

    2017/05 第46回日本IVR学会総会

  7. 研究奨励賞技術新人賞(防護分野)

    2016/12 公益社団法人日本放射線技術学会

Show all ︎Show 5

Papers 96

  1. Development of a headgear-based eye protection device for physicians performing fluoroscopy-guided bronchoscopy. International-journal

    Masaki Fujisawa, Yoshihiro Haga, Saki Takahira, Masahiro Sota, Toshiki Kato, Mitsuya Abe, Yuji Kaga, Yohei Inaba, Masatoshi Suzuki, Koichi Chida

    Journal of radiation research 2025/06/18

    DOI: 10.1093/jrr/rraf031  

    More details Close

    Fluoroscopy-guided bronchoscopy is an essential tool for diagnosing and treating lung diseases, particularly lung cancer. However, prolonged fluoroscopic exposure raises concerns regarding radiation-induced lens injuries in physicians, such as radiation cataracts. In response to the International Commission on Radiological Protection lowering the occupational lens dose limit to an average of 20 mSv/year over 5 years, there is an increasing need for effective lens protection during such procedures. This study has aimed to develop a novel lens protection device specifically designed for bronchoscopy physicians and evaluate its protective performance through a phantom study. The device consisted of a 0.175 mm lead (Pb) sheet positioned on the left side of the physician's head, secured with headgear to improve stability and comfort during prolonged use. A phantom study was conducted using a trunk phantom to simulate a patient and a head phantom to simulate a physician. The scattered radiation doses were measured at 15 locations on the phantom head using a radiophotoluminescence glass dosimeter, both with and without a protective device. The device demonstrated a protective effect of more than 80% for the left eye across all tested angles, whereas the right eye showed protection ranging from approximately 40% to 75% depending on the angle. This novel lens protection device has the potential to significantly reduce scattered radiation to the left eye while minimizing vision obstruction and discomfort. This offers a practical solution for radiation protection during bronchoscopy and may be applicable to other interventional procedures requiring fluoroscopic guidance.

  2. Development and Performance Evaluation of a Novel Mobile X-ray System for Use in Disaster Situations.

    Masaki Fujisawa, Yohei Inaba, Toshiki Kato, Masatoshi Suzuki, Koichi Chida

    The Tohoku journal of experimental medicine 2025/05/15

    DOI: 10.1620/tjem.2025.J054  

  3. A combination of lymphatic drug delivery of anti-CTLA-4 antibody and local radiotherapy for solid-tumor treatment. International-journal

    Koki Takagi, Ariunbuyan Sukhbaatar, Yohei Inaba, Shiro Mori, Tetsuya Kodama

    Cancer science 115 (12) 4021-4033 2024/12

    DOI: 10.1111/cas.16369  

    More details Close

    The combination of radiotherapy and immunotherapy is a promising approach that has been shown in clinical trials to improve significantly survival and response rates compared with monotherapy against solid tumor. Since anti-CTLA-4 antibodies block immunosuppressive signals mainly in the lymph nodes (LNs), efficient drug delivery to the lymphatic system is desirable. However, the immune checkpoint inhibitors, especially anti-CTLA-4 are currently administered intravenously (i.v.), resulting in limited efficacy in controlling solid tumor and inhibiting metastases, and the method of administration has not been optimized. Here, we show that a combination of local radiotherapy and administration of anti-CTLA-4 antibodies using a lymphatic drug delivery system (LDDS) suppresses solid tumor and metastases. We compared the efficacy of LDDS-based immunotherapy or radioimmunotherapy with i.v. administration in a solid-tumor model created by subcutaneous inoculation into LN-swollen mice with osteosarcoma cells. Tumor-bearing mice were divided into various groups (no treatment, immunotherapy [i.v. or LDDS], radiotherapy, and radioimmunotherapy [i.v. or LDDS]) and were observed for 28 days. Immunotherapy was administered with a cumulative dose of 10 mg/kg of anti-CTLA-4 monoclonal antibody, and radiotherapy was administered with a cumulative 8 Gy of fractionated X-ray irradiation. For immunotherapy alone, LDDS provided slight tumor growth inhibition but did not inhibit distant metastasis. For radioimmunotherapy, however, tumor growth was delayed and distant metastasis was suppressed compared with radiotherapy alone. In particular, the LDDS group achieved a high tumor-suppressive effect with T cell-mediated immune activity, indicating the efficacy of LDDS in radioimmunotherapy.

  4. Establishment of acquired radioresistant cells to fractionated radiation from hTERT-immortalized normal human epithelial cell

    Masatoshi Suzuki, Rio Isobe, Taku Sato, Ryoya Ishikawa, Keiji Suzuki, Yasushi Kino, Tomisato Miura, Yohei Inaba, Koichi Chida, Manabu Fukumoto

    Radiation Protection Dosimetry 200 (16-18) 1636-1640 2024/11/01

    DOI: 10.1093/rpd/ncae118  

    ISSN: 0144-8420

    eISSN: 1742-3406

  5. Analysis of cellular effects by continuous exposure AT low concentration of tritium

    Rio Isobe, Masatoshi Suzuki, Satoru Endo, Yasushi Kino, Ryoya Ishikawa, Yohei Inaba, Manabu Fukumoto, Koichi Chida

    Radiation Protection Dosimetry 200 (16-18) 1631-1635 2024/11/01

    DOI: 10.1093/rpd/ncae112  

    ISSN: 0144-8420

    eISSN: 1742-3406

  6. Radiation Exposure to the Brains of Interventional Radiology Staff: A Phantom Study

    Saya Ohno, Ryota Shindo, Satoe Konta, Keisuke Yamamoto, Yohei Inaba, Koichi Chida

    Bioengineering 11 (11) 2024/10

    DOI: 10.3390/bioengineering11111083  

    eISSN: 2306-5354

  7. Convenient real-time radiation monitoring and measurement device using phosphate glass with aluminum impurities

    Sota Orimo, Takeru Awano, Shun Akiyama, Saya Ohno, Satoe Konta, Ryota Sindo, Makoto Sakai, Osamu Hanaizumi, Yohei Inaba, Wataru Kada

    Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms 555 2024/10

    DOI: 10.1016/j.nimb.2024.165447  

    ISSN: 0168-583X

  8. Comparison of radiation-shielding curtains for endoscopic retrograde cholangiopancreatography staff. International-journal

    Hiroki Ishii, Koichi Chida, Yohei Inaba, Shu Onodera, Masahiro Sai, Masayuki Zuguchi

    Journal of radiological protection : official journal of the Society for Radiological Protection 2024/09/12

    DOI: 10.1088/1361-6498/ad7a06  

    More details Close

    Occupational radiation exposure to the eye lens of medical staff during endoscopic retrograde cholangiopancreatography (ERCP) should be kept low so as not to exceed annual dose limits. Dose should be low to avoid tissue reactions and minimizing stochastic effects. It is known that the head and neck of the staff are exposed to more scattered radiation in an over-couch tube system than in a C-arm system (under-couch tube). However, this is only true when radiation-shielding curtains are not used. This study aimed to compare the protection radiation to the occupationally exposed worker between a lead curtain mounted on a C-arm system and an ERCP-specific lead curtain mounted on an over-couch tube system. A phantom study simulating a typical setting for ERCP procedures was conducted, and the scattered radiation dose at four staff positions were measured. It was found that scattered radiation doses were higher in the C-arm with a lead curtain than in the over-couch tube with an ERCP-specific lead curtain at all positions measured in this study. It was concluded that the over-couch tube system with an ERCP-specific lead curtain would reduce the staff eye dose by less than one-third compared to the C-arm system with a lead curtain. For the C-arm system, it is necessary to consider more effective radiation protection measures for the upper body of the staff, such as a ceiling-suspended lead screen or another novel shielding that do not interfere with procedures.

  9. Evaluation of Radiation Doses Received by Physicians during Permanent 198Au Grain Implant Brachytherapy for Oral Cancer

    Yohei Inaba, Keiichi Jingu, Masaki Fujisawa, Kazuki Otomo, Hiroki Ishii, Toshiki Kato, Yuuki Murabayashi, Masatoshi Suzuki, Masayuki Zuguchi, Koichi Chida

    Applied Sciences (Switzerland) 14 (14) 2024/07

    DOI: 10.3390/app14146010  

    eISSN: 2076-3417

  10. Effect of backscatter radiation on the occupational eye-lens dose International-journal

    Saya Ohno, Satoe Konta, Ryota Shindo, Keisuke Yamamoto, Rio Isobe, Yohei Inaba, Masatoshi Suzuki, Masayuki Zuguchi, Koichi Chida

    Journal of Radiation Research 65 (4) 450-458 2024/07/01

    DOI: 10.1093/jrr/rrae034  

    ISSN: 0449-3060

    eISSN: 1349-9157

  11. Comparison of shielding effects of over-glasses-type and regular eyewear in terms of occupational eye dose reduction International-journal

    Ryota Shindo, Saya Ohno, Keisuke Yamamoto, Satoe Konta, Yohei Inaba, Masatoshi Suzuki, Masayuki Zuguchi, Koichi Chida

    Journal of Radiological Protection 44 (2) 2024/06

    DOI: 10.1088/1361-6498/ad4714  

    ISSN: 0952-4746

    eISSN: 1361-6498

  12. Basic Performance Evaluation of a Radiation Survey Meter That Uses a Plastic-Scintillation Sensor

    Keisuke Yamamoto, Ryota Shindo, Saya Ohno, Satoe Konta, Rio Isobe, Yohei Inaba, Masatoshi Suzuki, Yoshio Hosoi, Koichi Chida

    Sensors 2024/05

    DOI: 10.3390/s24102973  

  13. シンチレーションサーベイメータの温度補償機能の有無による温度依存性

    古川 未来, 礒部 理央, 大野 紗耶, 郷内 優作, 進藤 僚太, 山本 啓介, 稲葉 洋平, 千田 浩一

    日本放射線技術学会雑誌 80 (3) 279-286 2024/03

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  14. The 2024 Noto Peninsula Earthquake and the Strategy of Medical Assistance from the Tohoku University Hospital.

    Shinichi Egawa, Tadashi Ishii, Hajime Furukawa, Motoo Fujita, Yoshiko Abe, Aisa Sakamoto, Yohei Inaba, Katsunori Ono, Hideo Harigae, Motohiro Tsuboi, Shinichi Kuriyama, Hiroyuki Sasaki

    The Tohoku journal of experimental medicine 262 (1) 45-49 2024

    DOI: 10.1620/tjem.2024.J010  

    More details Close

    A moment magnitude (Mw) 7.5 earthquake (the Global IDentifire (GLIDE) number: # Q-2024-000001-JPN) struck the Noto Peninsula of Ishikawa Prefecture on 1 January 2024 at 16:10 (Japan Standard Time). The reversed fault, 150 km in length and subducting beneath the peninsula, resulted in maximum seismic intensity 7 shaking, triggered the tsunami, destroyed over 43 thousand buildings, and disrupted roads and lifelines. The disaster claimed 236 deaths, including 15 indirect disaster deaths as of Jan. 28, 2024. There were Disaster Base Hospitals (DBHs) in the region, which survived structurally but suffered from impaired functions and the surge of medical needs of affected people. The disaster medical system of Japan immediately responded and coordinated the hundreds of emergency medical teams (EMTs), i.e., the Japan Disaster Medical Assistance Team (DMAT), from all over the country. Tohoku University Hospital, which had the experience of the 2011 Great East Japan Earthquake (GEJE), joined the coordinated response, dispatching a chain of DMATs, which helped the medical and public health coordination in Wajima City. The medical and public health needs included injuries, non-communicable diseases, infectious diseases, mental health issues, and maternal and child health issues, which were similar in the affected communities in GEJE. Although the actual damage far exceeded expectations, the structural retrofitting and business continuity plans of DBHs and the coordinated response of the national disaster medical system enhanced the effectiveness of medical and public health response.

  15. Fundamental study on diagnostic reference level quantities for endoscopic retrograde cholangiopancreatography using a C-arm fluoroscopy system. International-journal

    Hiroki Ishii, Koichi Chida, Yohei Inaba, Keisuke Abe, Shu Onodera, Masayuki Zuguchi

    Journal of radiological protection : official journal of the Society for Radiological Protection 2023/11/08

    DOI: 10.1088/1361-6498/ad0a9d  

    More details Close

    The diagnostic reference level (DRL) is an effective tool for optimizing protection in medical exposures to patients. However, regarding air kerma at the patient entrance reference point (Ka,r), one of the DRL quantities for endoscopic retrograde cholangiopancreatography (ERCP), manufacturers use a variety of the International Electrotechnical Commission (IEC) and their own specific definitions of the reference point. The research question for this study was whetherKa,ris appropriate as a DRL quantity for ERCP. The purpose of this study was to evaluate the difference betweenKa,rand air kerma incident on the patient's skin surface (Ka,e) at the different height of the patient couch for a C-arm system. Fluoroscopy and radiography were performed using a C-arm system (Ultimax-i, Canon Medical Systems, Japan) and a over-table tube system (CUREVISTA Open, Fujifilm Healthcare, Japan).Ka,ewas measured by an ion chamber placed on the entrance surface of the phantom. Kerma-area product (PKA) andKa,rwere measured by a built-inPKAmeter and displayed on the fluoroscopy system.Ka,edecreased whileKa,rincreased as the patient couch moved away from the focal spot. The uncertainty of theKa,e/Ka,rratio due to the different height of the patient couch was estimated to be 75-94%.Ka,rmay not accurately representKa,e.PKAwas a robust DRL quantity that was independent of the patient couch height. We cautioned against optimizing patient doses in ERCP with DRLs set in terms ofKa,rwithout considering the patient couch height of the C-arm system. Therefore, we recommend thatKa,ris an inappropriate DRL quantity in ERCP using the C-arm system.

  16. シンチレータ式簡易測定器の諸特性に関する基礎検討

    礒部 理央, 古川 未来, 大野 紗耶, 進藤 遼太, 山本 啓介, 稲葉 洋平, 鈴木 正敏, 千田 浩一

    日本放射線安全管理学会誌 22 (2) 72-82 2023/11

    Publisher: (一社)日本放射線安全管理学会

    ISSN: 1347-1503

  17. Internal organ dose rate conversion coefficients of Japanese macaques to 134Cs,137Cs and 131I†. International-journal

    Yuta Takamura, Tsuyoshi Kajimoto, Kenichi Tanaka, Tomoya Yamamoto, Masatoshi Suzuki, Yohei Inaba, Koichi Chida, Manabu Fukumoto, Chary Rangacharyulu, Satoru Endo

    Journal of radiation research 64 (5) 804-810 2023/09/22

    DOI: 10.1093/jrr/rrad055  

    More details Close

    The purpose of this study was to estimate the internal dose of radiation in Japanese macaques (aka Nihonzaru or snow monkey) due to the Fukushima nuclear power plant accident. Images of a male Japanese macaque weighing ~10 kg were acquired using a multi-slice computed tomography (CT) scan with a 64-row segment detector. The CT images were used to create voxel phantoms of the bones, bone marrow, brain, eyes, heart, lungs, stomach, liver, spleen, pancreas, kidneys, intestines, bladder, testes, thyroid and miscellaneous tissue. The Particle and Heavy Ion Transport System (PHITS) Monte Carlo code was used to calculate the internal exposure rate conversion factors for 134Cs, 137Cs and 131I isotopes for the created voxel phantoms with a statistical precision higher than 1%. The PHITS-calculated energy deposits were compared with those for rhesus monkeys. The results showed that the fractions of energy deposits for β-radiation in different organs were almost identical between the two species. For γ-radiation, there was excellent agreement in the self-absorption rate with the approximate curve of the Japanese macaque, with an average deviation of 2%. The maximum deviation of 12% was for the kidney, which has two organs, so the error with the approximate curve is slightly larger due to the energy loss created between organs.

  18. Eye Lens Radiation Dose to Nurses during Cardiac Interventional Radiology: An Initial Study. International-journal

    Ayumi Yamada, Yoshihiro Haga, Masahiro Sota, Mitsuya Abe, Yuji Kaga, Yohei Inaba, Masatoshi Suzuki, Norio Tada, Masayuki Zuguchi, Koichi Chida

    Diagnostics (Basel, Switzerland) 13 (18) 2023/09/20

    DOI: 10.3390/diagnostics13183003  

    More details Close

    Although interventional radiology (IVR) is preferred over surgical procedures because it is less invasive, it results in increased radiation exposure due to long fluoroscopy times and the need for frequent imaging. Nurses engaged in cardiac IVR receive the highest lens radiation doses among medical workers, after physicians. Hence, it is important to measure the lens exposure of IVR nurses accurately. Very few studies have evaluated IVR nurse lens doses using direct dosimeters. This study was conducted using direct eye dosimeters to determine the occupational eye dose of nurses engaged in cardiac IVR, and to identify simple and accurate methods to evaluate the lens dose received by nurses. Over 6 months, in a catheterization laboratory, we measured the occupational dose to the eyes (3 mm dose equivalent) and neck (0.07 mm dose equivalent) of nurses on the right and left sides. We investigated the relationship between lens and neck doses, and found a significant correlation. Hence, it may be possible to estimate the lens dose from the neck badge dose. We also evaluated the appropriate position (left or right) of eye dosimeters for IVR nurses. Although there was little difference between the mean doses to the right and left eyes, that to the right eye was slightly higher. In addition, we investigated whether it is possible to estimate doses received by IVR nurses from patient dose parameters. There were significant correlations between the measured doses to the neck and lens, and the patient dose parameters (fluoroscopy time and air kerma), implying that these parameters could be used to estimate the lens dose. However, it may be difficult to determine the lens dose of IVR nurses accurately from neck badges or patient dose parameters because of variation in the behaviors of nurses and the procedure type. Therefore, neck doses and patient dose parameters do not correlate well with the radiation eye doses of individual IVR nurses measured by personal eye dosimeters. For IVR nurses with higher eye doses, more accurate measurement of the radiation doses is required. We recommend that a lens dosimeter be worn near the eyes to measure the lens dose to IVR nurses accurately, especially those exposed to relatively high doses.

  19. Evaluation of Lens Doses among Medical Staff Involved in Nuclear Medicine: Current Eye Radiation Exposure among Nuclear-Medicine Staff

    Masaki Fujisawa, Yoshihiro Haga, Masahiro Sota, Mitsuya Abe, Yuji Kaga, Yohei Inaba, Masatoshi Suzuki, Taiichiro Meguro, Yoshio Hosoi, Koichi Chida

    Applied Sciences 13 (16) 9182-9182 2023/08/12

    Publisher: MDPI AG

    DOI: 10.3390/app13169182  

    eISSN: 2076-3417

    More details Close

    The International Commission on Radiological Protection has lowered the annual equivalent eye-lens dose to 20 mSv. Although occupational exposure can be high in nuclear medicine (NM) departments, few studies have been conducted regarding eye-lens exposure among NM staff. This study aimed to estimate the annual lens doses of staff in an NM department and identify factors contributing to lens exposure. Four nurses and six radiographers performing positron emission tomography (PET) examinations and four radiographers performing radioisotope (RI) examinations (excluding PET) were recruited for this study. A lens dosimeter was attached near the left eye to measure the 3-mm-dose equivalent; a personal dosimeter was attached to the left side of the neck to measure the 1-cm- and 70-µm-dose equivalents. Measurements were acquired over six months, and the cumulative lens dose was doubled to derive the annual dose. Correlations between the lens and personal-dosimeter doses, between the lens dose and the numbers of procedures, and between the lens dose and the amounts of PET drugs (radiopharmaceuticals) injected were examined. Wilcoxon’s signed-rank test was used to compare lens and personal-dosimeter doses. The estimated annual doses were 0.93 ± 0.13 mSv for PET nurses, 0.71 ± 0.41 mSv for PET radiographers, and 1.10 ± 0.53 mSv for RI radiographers. For PET nurses, but not for PET or RI radiographers, there was a positive correlation between the numbers of procedures and lens doses and between amounts injected and lens doses. There was a significant difference between the lens and personal-dosimeter doses of PET nurses. The use of protective measures, such as shielding, should prevent NM staff from receiving lens doses > 20 mSv/year. However, depending on the height of the protective shield, PET nurses may be unable to assess the lens dose accurately using personal dosimeters.

  20. 水晶体用線量計DOSIRISの改良試作型ヘッドセットに関する初期検討

    今田 聡恵, 芳賀 喜裕, 曽田 真宏, 阿部 美津也, 加賀 勇治, 稲葉 洋平, 千田 浩一

    臨床放射線 68 (7) 723-729 2023/07

    Publisher: 金原出版(株)

    ISSN: 0009-9252

  21. 無線応答式新型リアルタイム線量計の電波応答に関する検討

    服部 兼進, 加藤 聖規, 山田 歩実, 藤沢 昌輝, 安野 ひかる, 芳賀 喜裕, 曽田 真宏, 加賀 勇治, 阿部 美津也, 稲葉 洋平, 千田 浩一

    日本放射線安全管理学会誌 22 (1) 3-9 2023/06

    Publisher: (一社)日本放射線安全管理学会

    ISSN: 1347-1503

  22. PCI術者の水晶体線量のリアルタイム測定に関する初期検討

    加藤 聖規, 藤沢 昌輝, 服部 兼進, 山田 歩実, 芳賀 喜裕, 加賀 勇治, 阿部 美津也, 稲葉 洋平, 千田 浩一

    日本放射線安全管理学会誌 22 (1) 10-18 2023/06

    Publisher: (一社)日本放射線安全管理学会

    ISSN: 1347-1503

  23. Spatial Scattering Radiation to the Radiological Technologist during Medical Mobile Radiography. International-journal

    Kazuki Otomo, Yohei Inaba, Keisuke Abe, Mana Onodera, Tomohiro Suzuki, Masahiro Sota, Yoshihiro Haga, Masatoshi Suzuki, Masayuki Zuguchi, Koichi Chida

    Bioengineering (Basel, Switzerland) 10 (2) 2023/02/16

    DOI: 10.3390/bioengineering10020259  

    More details Close

    Mobile radiography allows for the diagnostic imaging of patients who cannot move to the X-ray examination room. Therefore, mobile X-ray equipment is useful for patients who have difficulty with movement. However, staff are exposed to scattered radiation from the patient, and they can receive potentially harmful radiation doses during radiography. We estimated occupational exposure during mobile radiography using phantom measurements. Scattered radiation distribution during mobile radiography was investigated using a radiation survey meter. The efficacy of radiation-reducing methods for mobile radiography was also evaluated. The dose decreased as the distance from the X-ray center increased. When the distance was more than 150 cm, the dose decreased to less than 1 μSv. It is extremely important for radiological technologists (RTs) to maintain a sufficient distance from the patient to reduce radiation exposure. The spatial dose at eye-lens height increases when the bed height is high, and when the RT is short in stature and abdominal imaging is performed. Maintaining sufficient distance from the patient is also particularly effective in limiting radiation exposure of the eye lens. Our results suggest that the doses of radiation received by staff during mobile radiography are not significant when appropriate radiation protection is used. To reduce exposure, it is important to maintain a sufficient distance from the patient. Therefore, RTs should bear this is mind during mobile radiography.

  24. Evaluation of a New Real-Time Dosimeter Sensor for Interventional Radiology Staff

    Kenshin Hattori, Yohei Inaba, Toshiki Kato, Masaki Fujisawa, Hikaru Yasuno, Ayumi Yamada, Yoshihiro Haga, Masatoshi Suzuki, Masayuki Zuguchi, Koichi Chida

    Sensors 23 (1) 2023/01

    DOI: 10.3390/s23010512  

    ISSN: 1424-8220

  25. 経皮的冠動脈形成術における治療区域別被ばく線量とDRLs 2020の比較

    増渕 裕介, 千田 浩一, 稲葉 洋平, 景山 倫也, 嶋田 涼香, 山下 明

    日本放射線技術学会雑誌 78 (11) 1306-1313 2022/11

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  26. PET検査に従事する看護師の水晶体被ばく線量に関する基礎検討

    藤沢 昌輝, 芳賀 善裕, 曽田 真宏, 加賀 勇治, 阿部 美津也, 稲葉 洋平, 鈴木 正敏, 細井 義夫, 千田 浩一

    臨床放射線 67 (10) 1075-1083 2022/10

    Publisher: 金原出版(株)

    ISSN: 0009-9252

  27. 新型コロナウイルス感染症軽症者等宿泊療養施設における管理課題解決のための情報共有・往診システムの構築

    高山 真, 有田 龍太郎, 小野 理恵, 只野 恭教, 菊地 章子, 稲葉 洋平, 中村 直毅, 阿部 倫明, 石井 正

    日本医療・病院管理学会誌 59 (4) 157-167 2022/10

    Publisher: (一社)日本医療・病院管理学会

    ISSN: 1882-594X

    eISSN: 2185-422X

  28. COVID-19-Related Symptoms during the SARS-CoV-2 Omicron (B.1.1.529) Variant Surge in Japan.

    Tetsuya Akaishi, Shigeki Kushimoto, Yukio Katori, Noriko Sugawara, Hiroshi Egusa, Kaoru Igarashi, Motoo Fujita, Shigeo Kure, Shin Takayama, Michiaki Abe, Akiko Kikuchi, Minoru Ohsawa, Kota Ishizawa, Yoshiko Abe, Hiroyuki Imai, Yohei Inaba, Yoko Iwamatsu-Kobayashi, Takashi Nishioka, Ko Onodera, Tadashi Ishii

    The Tohoku journal of experimental medicine 258 (2) 103-110 2022/09/06

    DOI: 10.1620/tjem.2022.J067  

    More details Close

    The exact profiles of the clinical symptoms related to the SARS-CoV-2 Omicron variant (B.1.1.529) remain largely uncertain. Therefore, this study aimed to clarify the clinical manifestations of infection with this variant. We enrolled individuals who were tested by quantitative nasopharyngeal swab reverse transcription-polymerase chain reaction (RT-PCR) test at a large screening center in a city of Japan during the B.1.1.529 Omicron variant wave between January and May 2022, after contact with COVID-19 patients. Swab tests were planned to be performed approximately 4-5 days after contact. The presence of COVID-19-related symptoms was assessed at the swab test site. Among the 2,507 enrolled individuals, 943 (37.6%) were RT-PCR test-positive and 1,564 (62.4%) were test-negative. Among the 943 PCR test-positive participants, the prevalence of the symptoms was as follows: 47.3% with cough, 32.9% with sore throat, 18.4% with fatigability, 12.7% with fever of ≥ 37.5℃, 9.9% with dyspnea, 2.1% with dysosmia, and 1.4% with dysgeusia. The prevalence of cough, sore throat, dyspnea, and fatigability was higher among adults aged ≥ 18 years than among children and adolescents. The prevalence of dysosmia and dysgeusia remarkably decreased during the Omicron wave (1-3%) compared to during the pre-Omicron variant waves (15-25%). In summary, common COVID-19-related symptoms during the Omicron variant wave included cough and sore throat, followed by fatigability, fever, and dyspnea. The prevalence of most of these symptoms was higher in adults than in non-adults. The prevalence of dysosmia and dysgeusia remarkably decreased with the Omicron variant than with pre-Omicron variants.

  29. Effectiveness of third vaccine dose for coronavirus disease 2019 during the Omicron variant pandemic: a prospective observational study in Japan. International-journal

    Tetsuya Akaishi, Shigeki Kushimoto, Yukio Katori, Noriko Sugawara, Hiroshi Egusa, Kaoru Igarashi, Motoo Fujita, Shigeo Kure, Shin Takayama, Michiaki Abe, Akiko Kikuchi, Minoru Ohsawa, Kota Ishizawa, Yoshiko Abe, Hiroyuki Imai, Yohei Inaba, Yoko Iwamatsu-Kobayashi, Takashi Nishioka, Ko Onodera, Tadashi Ishii

    Scientific reports 12 (1) 13589-13589 2022/08/10

    DOI: 10.1038/s41598-022-17990-7  

    More details Close

    The administration of a third booster dose of messenger ribonucleic acid (mRNA) vaccines against coronavirus disease 2019 (COVID-19) has progressed worldwide. Since January 2022, Japan has faced a nationwide outbreak caused by the Omicron variant, which occurred simultaneously with the progression of mass vaccination with the third booster dose. Therefore, this study evaluated the effectiveness of the third dose of vaccine by reverse transcription-polymerase chain reaction (RT-PCR) test using nasopharyngeal swab samples from adults aged ≥ 18 years tested after having close contact with COVID-19 cases between January and May 2022. Participants who completed only one dose were excluded from the study. Among the 928 enrolled participants, 139 had never been vaccinated, 609 had completed two doses, 180 had completed three doses before the swab test, and the overall RT-PCR test positivity rate in each group was 48.9%, 46.0%, and 32.2%, respectively. The vaccine effectiveness of the third dose to prevent infection after close contact was approximately 40% (95% confidence interval: 20-60%), which was the highest at 10-70 days after receiving the third dose. In conclusion, the effectiveness of the three-dose mRNA COVID-19 vaccine after close contact during the Omicron outbreak is approximately 40%.

  30. 新型ハイブリッドサーベイメータの基本特性 空間散乱線量の測定に関して

    大森 悠斗, 石沢 祥子, 川口 和奏, 巻 周星, 山田 芙美佳, 村林 優樹, 稲葉 洋平, 千田 浩一

    日本放射線安全管理学会誌 21 (1) 2-9 2022/06

    Publisher: (一社)日本放射線安全管理学会

    ISSN: 1347-1503

  31. Ionizing radiation reduces glutathione levels in the eye: A pilot study

    Lue Sun, Yohei Inaba, Yu Sogo, Naoki Kunugita, Koichi Chida, Takashi Moritake

    Journal of Radiation Research and Applied Sciences 15 (2) 106-110 2022/06

    Publisher: Elsevier BV

    DOI: 10.1016/j.jrras.2022.05.012  

    ISSN: 1687-8507

  32. Effectiveness of mRNA COVID-19 Vaccines in Japan during the Nationwide Pandemic of the Delta Variant.

    Tetsuya Akaishi, Shigeki Kushimoto, Yukio Katori, Noriko Sugawara, Kaoru Igarashi, Motoo Fujita, Shigeo Kure, Shin Takayama, Michiaki Abe, Akiko Kikuchi, Kota Ishizawa, Yoshiko Abe, Hiroyuki Imai, Yohei Inaba, Yoko Iwamatsu-Kobayashi, Takashi Nishioka, Ko Onodera, Tadashi Ishii

    The Tohoku journal of experimental medicine 257 (1) 1-6 2022/05/13

    DOI: 10.1620/tjem.2022.J012  

    More details Close

    The coronavirus disease 2019 (COVID-19) pandemic, caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), remained a major global health concern in 2021. To suppress the spread of infection, mass vaccinations have been performed across countries worldwide. In Japan, vaccinations of the first and second doses for most of the nation were performed during the nationwide outbreak of the B.1.617.2 (Delta) variant with the L452R spike protein mutation, and the effectiveness of the vaccinations to suppress the spread of COVID-19 among the people in Japan remains uncertain. In this study, adults aged ≥18 years, who were in contact with patients with COVID-19 and underwent nasopharyngeal swab reverse transcription-polymerase chain reaction (RT-PCR) tests during August and September 2021 at a mass screening test center in Japan, were enrolled. In this period, more than 95% of the COVID-19 infections were reportedly caused by the Delta variant. As a result, a total of 784 adults with recent contact history, including 231 (29.5%) RT-PCR test-positive cases, were enrolled. The test positivity rate was lower in individuals who had been vaccinated twice than in unvaccinated individuals (12.5% vs. 39.0%, p < 0.0001), with the risk ratio of 0.32 (95% confidence interval 0.23-0.46). The vaccine effectiveness was the highest between 7-90 days after the second vaccine dose. In conclusion, two doses of mRNA COVID-19 vaccines effectively suppressed transmission in Japan during the nationwide pandemic of the Delta variant, estimated to have prevented 50-80% of the infection.

  33. Occupational eye dose correlation with neck dose and patient-related quantities in interventional cardiology procedures.

    Hiroki Ishii, Koichi Chida, Ko Satsurai, Yoshihiro Haga, Yuji Kaga, Mitsuya Abe, Yohei Inaba, Masayuki Zuguchi

    Radiological physics and technology 15 (1) 54-62 2022/03

    DOI: 10.1007/s12194-022-00650-w  

    More details Close

    Occupational eye dose monitoring during interventional radiology and interventional cardiology is important to avoid radiation-induced cataracts. The aim of this study was to assess the eye dose correlation with neck dose and patient-related quantities for interventional cardiology physicians and nurses. The originality of this study lies in obtaining correlations between the location of the dosimeter and eye dose radiation readings among different procedures and practitioners. The doses were measured for each procedure (18 procedures of coronary angiography and 16 procedures of percutaneous coronary intervention) using an active personal dosimeter. The eye dose for physicians was not correlated with the neck dose. The eye dose for nurses had a good correlation with the neck dose during both coronary angiography (R2 = 0.91) and percutaneous coronary intervention (R2 = 0.93). Kerma-area product values may be used for a rough estimation of the eye dose for physicians during routine coronary angiography procedures (R2 = 0.76). For nurses, the neck dose is a good proxy for the eye dose during coronary angiography and percutaneous coronary intervention procedures.

  34. Radiation Eye Dose for Physicians in CT Fluoroscopy-Guided Biopsy. International-journal

    Yohei Inaba, Shin Hitachi, Munenori Watanuki, Koichi Chida

    Tomography (Ann Arbor, Mich.) 8 (1) 438-446 2022/02/08

    DOI: 10.3390/tomography8010036  

    More details Close

    It is important to evaluate the radiation eye dose (3 mm dose equivalent, Hp (3)) received by physicians during computed tomography fluoroscopy (CTF)-guided biopsy, as physicians are close to the source of scattered radiation. In this study, we measured the radiation eye dose in Hp (3) received by one physician during CTF in a timeframe of 18 months using a direct eye dosimeter, the DOSIRISTM. The physician placed eye dosimeters above and under their lead (Pb) eyeglasses. We recorded the occupational radiation dose received using a neck dosimeter, gathered CT dose-related parameters (e.g., CT-fluoroscopic acquisition number, CT-fluoroscopic time, and CT-fluoroscopic mAs), and performed a total of 95 procedures during CTF-guided biopsies. We also estimated the eye dose (Hp (3)) received using neck personal dosimeters and CT dose-related parameters. The physician eye doses (right and left side) received in terms of Hp (3) without the use of Pb eyeglasses for 18 months were 2.25 and 2.06 mSv, respectively. The protective effect of the Pb eyeglasses (0.5 mm Pb) on the right and left sides during CTF procedures was 27.8 and 37.5%, respectively. This study proved the existence of significant correlations between the eye and neck dose measurement (right and left sides, R2 = 0.82 and R2 = 0.55, respectively) in physicians. In addition, we found significant correlations between CT-related parameters, such as CT-fluoroscopy mAs, and radiation eye doses (right and left sides, R2 = 0.50 and R2 = 0.52, respectively). The eye dose of Hp (3) received in CTF was underestimated when evaluated using neck dosimeters. Therefore, we suggest that the physician involved in CTF use a direct eye dosimeter such as the DOSIRIS for the accurate evaluation of their eye lens dose.

  35. 仙台市内におけるCOVID-19患者への往診X線撮影 東北大学診療所ドライブスルー型PCR検査とホテル療養所往診X線撮影の実際

    稲葉 洋平

    日本放射線技術学会東北支部雑誌 (31) np21-np24 2022/01

    Publisher: (公社)日本放射線技術学会-東北支部

  36. 医療スタッフ用新型リアルタイム線量計の角度特性に関する検討

    服部 兼進, 加藤 聖規, 山田 歩実, 藤沢 昌輝, 安野 ひかる, 芳賀 喜裕, 曽田 真宏, 加賀 勇治, 阿部 美津也, 稲葉 洋平, 千田 浩一

    日本放射線技術学会東北支部雑誌 (31) np119-np120 2022/01

    Publisher: (公社)日本放射線技術学会-東北支部

  37. 防護眼鏡のX線の入射方向の違いによる遮蔽効果の基礎検討 鉛当量の異なる眼鏡を用いたファントム実験

    礒部 理央, 大野 紗耶, 郷内 優作, 進藤 僚太, 古川 未来, 山本 啓介, 遠藤 美芽, 稲葉 洋平, 千田 浩一

    日本放射線技術学会東北支部雑誌 (31) np121-np122 2022/01

    Publisher: (公社)日本放射線技術学会-東北支部

  38. 放射線防護ドレープによるIVR従事者の水晶体被ばく低減に関するファントムを用いた基礎実験

    巻 周星, 大森 悠斗, 村林 優樹, 大友 一輝, 芳賀 善裕, 曽田 真宏, 阿部 美津弥, 加賀 勇治, 千田 浩一, 稲葉 洋平

    日本放射線技術学会東北支部雑誌 (31) np123-np124 2022/01

    Publisher: (公社)日本放射線技術学会-東北支部

  39. 心血管インターベンションに携わる看護師における水晶体被ばく線量の推定方法

    山田 歩実, 大友 一輝, 佐藤 文貴, 千田 浩一, 稲葉 洋平, 芳賀 喜裕, 曽田 真宏, 加賀 勇治, 加藤 砂江子

    日本放射線技術学会東北支部雑誌 (31) np127-np128 2022/01

    Publisher: (公社)日本放射線技術学会-東北支部

  40. プラスチックシンチレータを用いたβ線用サーベイメータの基本特性

    山本 啓介, 礒部 理央, 大野 紗耶, 郷内 優作, 進藤 僚太, 古川 未来, 稲葉 洋平, 千田 浩一

    日本放射線技術学会東北支部雑誌 (31) np162-np163 2022/01

    Publisher: (公社)日本放射線技術学会-東北支部

  41. GMサーベイメータの温度依存性に関する基礎的検討

    郷内 優作, 礒部 理央, 大野 紗耶, 古川 未来, 進藤 僚太, 山本 啓介, 稲葉 洋平, 千田 浩一

    日本放射線技術学会東北支部雑誌 (31) np166-np167 2022/01

    Publisher: (公社)日本放射線技術学会-東北支部

  42. 心臓カテーテルインターベンションに携わる看護師の水晶体被ばく 水晶体線量の左右差に関する比較評価

    山田 歩実, 大友 一輝, 佐藤 文貴, 芳賀 喜裕, 曽田 真宏, 加賀 勇治, 阿部 美津也, 加藤 砂江子, 稲葉 洋平, 千田 浩一

    日本放射線安全管理学会誌 20 (2) 52-60 2021/11

    Publisher: (一社)日本放射線安全管理学会

    ISSN: 1347-1503

  43. COVID-19 Transmission at Schools in Japan.

    Tetsuya Akaishi, Shigeki Kushimoto, Yukio Katori, Noriko Sugawara, Kaoru Igarashi, Motoo Fujita, Shigeo Kure, Shin Takayama, Michiaki Abe, Junichi Tanaka, Akiko Kikuchi, Yoshiko Abe, Hiroyuki Imai, Yohei Inaba, Yoko Iwamatsu-Kobayashi, Takashi Nishioka, Ko Onodera, Tadashi Ishii

    The Tohoku journal of experimental medicine 255 (3) 239-246 2021/11

    DOI: 10.1620/tjem.255.239  

    More details Close

    The coronavirus disease 2019 (COVID-19) pandemic, caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), remains a global public health concern in 2021. However, the risk of attending schools during the pandemic remains unevaluated. This study estimated the secondary transmission rate at schools using the results of a real-time reverse transcription-polymerase chain reaction (RT-PCR) screening test performed between July 2020 and April 2021, before starting the nationwide mass vaccination. A total of 1,924 students (20 RT-PCR-positive; 1.0%) from 52 schools or preschools were evaluated, together with 1,379 non-adults (95 RT-PCR-positive; 6.9%) exposed to SARS-CoV-2 in non-school environments. Assuming that the infectious index cases were asymptomatic and the transmission at schools followed a Bernoulli process, we estimated the probability of transmission after each contact at school as approximately 0.005 (0.5% per contact) with the current infection prevention measures at schools in Japan (i.e., hand hygiene, physical distancing, wearing masks, and effective ventilation). Furthermore, assuming that all children are capable of carrying the infection, then contact between an index case and 20-30 students per day at schools would yield the expected value for secondary cases of ≥ 1.0, during the 10 days of the infectious period. In conclusion, with the current infection prevention measures at schools in Japan, secondary transmission at schools would occur in approximately every 200 contacts. When considering this rate, compliance with the current infection prevention measures at schools and early detection and quarantine of the index cases would be effective in preventing the spread of COVID-19 at schools.

  44. Analysis of whole-blood antioxidant capacity after chronic and localized irradiation using the i-STrap method. International-journal

    Lue Sun, Yohei Inaba, Yu Sogo, Kumi Morikawa, Naoki Kunugita, Koichi Chida, Takashi Moritake

    Journal of radiation research 63 (1) 30-35 2021/10/27

    DOI: 10.1093/jrr/rrab099  

    ISSN: 0449-3060

    eISSN: 1349-9157

  45. Discriminatory Value of Self-reported Olfactory Dysfunction in the Prediction of Coronavirus Disease 2019.

    Tetsuya Akaishi, Shigeki Kushimoto, Yukio Katori, Shigeo Kure, Kaoru Igarashi, Motoo Fujita, Shin Takayama, Michiaki Abe, Akiko Kikuchi, Junichi Tanaka, Yoshiko Abe, Hiroyuki Imai, Yohei Inaba, Yoko Iwamatsu-Kobayashi, Takashi Nishioka, Ko Onodera, Tadashi Ishii

    Internal medicine (Tokyo, Japan) 60 (18) 2905-2910 2021/09/15

    DOI: 10.2169/internalmedicine.7238-21  

    More details Close

    Objective Coronavirus disease 2019 (COVID-19), which is caused by severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2), remains the world's largest public health concern in 2021. A history of close contact with infectious patients is a factor that predicts a positive SARS-CoV-2 test result. Meanwhile, the precise predictive value of symptoms suggestive of COVID-19 has not been fully elucidated. This study aimed to clarify the predictive and discriminatory value of each clinical symptom suggestive of COVID-19. Methods This study enrolled participants who were tested for SARS-CoV-2 by reverse transcription polymerase chain reaction using a nasopharyngeal swab between November 2020 and January 2021. All enrolled patients were evaluated for data regarding the presence and closeness of contact with infectious patients and comprehensive clinical features (i.e., fever, cough, dyspnea, fatigue, dysosmia, and dysgeusia). Results Among the 1,744 tested participants, 144 tested positive for SARS-CoV-2. In the test-positive group, self-reported cough, fatigue, dysosmia, and dysgeusia were significant predictors of COVID-19, independent from a history of close contact. In particular, the presence of dysosmia was the strongest predictor of COVID-19 in both univariate and multivariate analyses. Among the 42 patients with self-reported dysosmia, 25 (59.5%) were SARS-CoV-2 test-positive. Self-reported dysosmia was reported by 25 (17.4%) of the 144 patients who tested positive for SARS-CoV-2, and 15 (60.0%) of the 25 COVID-19 patients with dysosmia had accompanying dysgeusia. Conclusion The presence of dysosmia was reported by 10-25% of patients with COVID-19, and is a significant predictor of COVID-19 infection, independent from a history of close contact.

  46. Non-Lead Protective Aprons for the Protection of Interventional Radiology Physicians from Radiation Exposure in Clinical Settings: An Initial Study. International-journal

    Mamoru Kato, Koichi Chida, Masato Munehisa, Tadaya Sato, Yohei Inaba, Masatoshi Suzuki, Masayuki Zuguchi

    Diagnostics (Basel, Switzerland) 11 (9) 2021/09/03

    DOI: 10.3390/diagnostics11091613  

    More details Close

    Radiation protection/evaluation during interventional radiology (IVR) poses a very important problem. Although IVR physicians should wear protective aprons, the IVR physician may not tolerate wearing one for long procedures because protective aprons are generally heavy. In fact, orthopedic problems are increasingly reported in IVR physicians due to the strain of wearing heavy protective aprons during IVR. In recent years, non-Pb protective aprons (lighter weight, composite materials) have been developed. Although non-Pb protective aprons are more expensive than Pb protective aprons, the former aprons weigh less. However, whether the protective performance of non-Pb aprons is sufficient in the IVR clinical setting is unclear. This study compared the ability of non-Pb and Pb protective aprons (0.25- and 0.35-mm Pb-equivalents) to protect physicians from scatter radiation in a clinical setting (IVR, cardiac catheterizations, including percutaneous coronary intervention) using an electric personal dosimeter (EPD). For radiation measurements, physicians wore EPDs: One inside a personal protective apron at the chest, and one outside a personal protective apron at the chest. Physician comfort levels in each apron during procedures were also evaluated. As a result, performance (both the shielding effect (98.5%) and comfort (good)) of the non-Pb 0.35-mm-Pb-equivalent protective apron was good in the clinical setting. The radiation-shielding effects of the non-Pb 0.35-mm and Pb 0.35-mm-Pb-equivalent protective aprons were very similar. Therefore, non-Pb 0.35-mm Pb-equivalent protective aprons may be more suitable for providing radiation protection for IVR physicians because the shielding effect and comfort are both good in the clinical IVR setting. As non-Pb protective aprons are nontoxic and weigh less than Pb protective aprons, non-Pb protective aprons will be the preferred type for radiation protection of IVR staff, especially physicians.

  47. 東北大学病院総合診療科におけるCOVID-19療養者往診の取り組み

    有田 龍太郎, 高山 真, 小野 理恵, 菊地 章子, 大澤 稔, 齊藤 奈津美, 鈴木 聡子, 小野寺 保, 中村 直毅, 稲葉 洋平, 中山 雅晴, 石井 正

    日本病院総合診療医学会雑誌 17 (臨増2) 172-172 2021/09

    Publisher: (一社)日本病院総合診療医学会

    ISSN: 2185-8136

    eISSN: 2758-7878

  48. 心臓・血管系IVRに従事する医師の水晶体被ばく線量の左右差に関する検討

    大友 一輝, 佐藤 文貴, 芳賀 喜裕, 曽田 真宏, 加賀 勇治, 阿部 美津也, 伊澤 毅, 村林 優樹, 稲葉 洋平, 千田 浩一

    臨床放射線 66 (9) 903-913 2021/09

    Publisher: 金原出版(株)

    ISSN: 0009-9252

  49. Impacts of Natural Environmental Factors and Prevalence of Airway Symptoms on the Local Spread of COVID-19: A Time-Series Analysis in Regional COVID-19 Epidemics.

    Tadashi Ishii, Shigeki Kushimoto, Yukio Katori, Shigeo Kure, Kaoru Igarashi, Motoo Fujita, Noriko Sugawara, Shin Takayama, Michiaki Abe, Junichi Tanaka, Akiko Kikuchi, Yoshiko Abe, Hiroyuki Imai, Yohei Inaba, Yoko Iwamatsu-Kobayashi, Takashi Nishioka, Ko Onodera, Tetsuya Akaishi

    The Tohoku journal of experimental medicine 254 (2) 89-100 2021/06

    DOI: 10.1620/tjem.254.89  

    More details Close

    Coronavirus disease 2019 (COVID-19), caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), is the world's largest public health concern in 2021. This study evaluated the associations of the prevalence of airway symptoms among the tested individuals and data regarding the natural environmental factors with the weekly number of newly diagnosed COVID-19 patients in Sendai City (Nt). For the derivatives of the screening test results, data from individuals with a contact history who underwent nasopharyngeal swab reverse transcription-polymerase chain reaction (RT-PCR) testing between July 2020 and April 2021 (6,156 participants, including 550 test-positive patients) were used. The value of Nt correlated with the weekly RT-PCR test-positive rate after close contact, prevalence of cough symptoms in test-positive individuals or in test-negative individuals, lower air temperature, lower air humidity, and higher wind speed. The weekly test-positive rate correlated with lower air humidity and higher wind speed. In cross-correlation analyses, natural environmental factors correlated with the regional epidemic status on a scale of months, whereas the airway symptoms among non-COVID-19 population affected on a scale of weeks. When applying an autoregression model to the serial data of Nt, large-scale movements of people were suggested to be another factor to influence the local epidemics on a scale of days. In conclusion, the prevalence of cough symptoms in the local population, lower air humidity or higher wind speed, and large-scale movements of people in the locality would jointly influence the local epidemic status of COVID-19.

  50. Evaluation of novel X-ray protective eyewear in reducing the eye dose to interventional radiology physicians. International-journal

    Mime Endo, Yoshihiro Haga, Masahiro Sota, Akiko Tanaka, Kazuki Otomo, Yuuki Murabayashi, Mitsuya Abe, Yuji Kaga, Yohei Inaba, Msatoshi Suzuki, Taiichiro Meguro, Koichi Chida

    Journal of radiation research 62 (3) 414-419 2021/05/12

    DOI: 10.1093/jrr/rrab014  

    More details Close

    The new recommendation of the International Commission on Radiological Protection for occupational eye dose is an equivalent dose limit to the eye of 20 mSv year-1, averaged over a 5-year period. This recommendation is a drastic reduction from the previous limit of 150 mSv year-1. Hence, it is important to protect physicians' eyes from X-ray radiation. Particularly in interventional radiology (IVR) procedures, many physicians use protective lead (Pb) glasses to reduce their occupational exposure. This study assessed the shielding effects of novel 0.07 mm Pb glasses. The novel glasses (XR-700) have Pb-acrylic lens molded in three dimensions. We studied the novel type of 0.07 mm Pb glasses over a period of seven consecutive months. The eye dose occupational radiation exposure of seven IVR physicians was evaluated during various procedures. All IVR physicians wore eye dosimeters (DOSIRIS™) close to the left side of the left eye. To calculate the shielding effects of the glasses, this same type of eye dosimeter was worn both inside and outside of the Pb lenses. The average shielding effect of the novel glasses across the seven physicians was 61.4%. Our results suggest an improved shielding effect for IVR physicians that use these glasses. No physician complained that the new glasses were uncomfortable; therefore comfort is not a problem. The lightweight glasses were acceptable to IVR physicians, who often must perform long procedures. Thus, the novel glasses are comfortable and reasonably protective. Based on the results of this study, we recommend that IVR physicians use these novel 0.07 mm Pb glasses to reduce their exposure.

  51. Occupational Radiation Dose to Eye Lenses in CT-Guided Interventions Using MDCT-Fluoroscopy. International-journal

    Yohei Inaba, Shin Hitachi, Munenori Watanuki, Koichi Chida

    Diagnostics (Basel, Switzerland) 11 (4) 2021/04/02

    DOI: 10.3390/diagnostics11040646  

    More details Close

    In computed tomography (CT)-guided interventions (CTIs), physicians are close to a source of scattered radiation. The physician and staff are at high risk of radiation-induced injury (cataracts). Thus, dose-reducing measures for physicians are important. However, few previous reports have examined radiation doses to physicians in CTIs. This study evaluated the radiation dose to the physician and medical staff using multi detector (MD)CT-fluoroscopy, and attempted to understand radiation-protection and -reduction methods. The procedures were performed using an interventional radiology (IVR)-CT system. We measured the occupational radiation dose (physician and nurse) using a personal dosimeter in real-time, gathered CT-related parameters (fluoroscopy time, mAs, CT dose index (CTDI), and dose length product (DLP)), and performed consecutive 232 procedures in CT-guided biopsy. Physician doses (eye lens, neck, and hand; μSv, average ± SD) in our CTIs were 39.1 ± 36.3, 23.1 ± 23.7, and 28.6 ± 31.0, respectively. Nurse doses (neck and chest) were lower (2.3 ± 5.0 and 2.4 ± 4.4, respectively) than the physician doses. There were significant correlations between the physician doses (eye and neck) and related factors, such as CT-fluoroscopy mAs (eye dose: r = 0.90 and neck dose: r = 0.83). We need to understand the importance of reducing/optimizing the dose to the physician and medical staff in CTIs. Our study suggests that physician and staff doses were not significant when the procedures were performed with the appropriate radiation protection and low-dose techniques.

  52. Total body irradiation causes a chronic decrease in antioxidant levels. International-journal

    Lue Sun, Yohei Inaba, Yu Sogo, Atsuo Ito, Mahesh Bekal, Koichi Chida, Takashi Moritake

    Scientific reports 11 (1) 6716-6716 2021/03/24

    DOI: 10.1038/s41598-021-86187-1  

    eISSN: 2045-2322

  53. Predictors of sars-cov-2 positivity based on rt-pcr swab tests at a drive-through outpatient clinic for covid-19 screening in japan

    Tadashi Ishii, Shigeki Kushimoto, Yukio Katori, Shigeo Kure, Kaoru Igarashi, Motoo Fujita, Shin Takayama, Michiaki Abe, Junichi Tanaka, Akiko Kikuchi, Yoshiko Abe, Hiroyuki Imai, Yohei Inaba, Yoko Iwamatsu-Kobayashi, Takashi Nishioka, Ko Onodera, Tetsuya Akaishi

    Tohoku Journal of Experimental Medicine 253 (2) 101-108 2021

    DOI: 10.1620/tjem.253.101  

    ISSN: 0040-8727

    eISSN: 1349-3329

  54. 空間線量測定用新型サーベイメータの性能評価

    森島 貴顕, 千田 浩一, 稲葉 洋平, 千葉 昌弘, 千葉 浩生

    臨床放射線 65 (12) 1327-1333 2020/11

    Publisher: 金原出版(株)

    ISSN: 0009-9252

  55. Hybrid operating room system for the treatment of thoracic and abdominal aortic aneurysms: Evaluation of the radiation dose received by patients International-journal

    Yoshihiro Haga, Koichi Chida, Masahiro Sota, Yuji Kaga, Mitsuya Abe, Yohei Inaba, Masatoshi Suzuki, Taiichiro Meguro, Masayuki Zuguchi

    Diagnostics 10 (10) 2020/10/19

    DOI: 10.3390/diagnostics10100846  

    eISSN: 2075-4418

  56. An initial investigation of a wireless patient radiation dosimeter for use in interventional radiology

    Yohei Inaba, Koichi Chida, Yuuki Murabayashi, Mime Endo, Kazuki Otomo, Masayuki Zuguchi

    Radiological Physics and Technology 13 (3) 321-326 2020/09/01

    DOI: 10.1007/s12194-020-00575-2  

    ISSN: 1865-0333

    eISSN: 1865-0341

  57. 肝動脈化学塞栓療法施行肝細胞癌患者の累積被ばく線量の実態調査

    増渕 裕介, 千田 浩一, 稲葉 洋平, 中野 繁明, 山下 明, 水沼 仁孝

    日本インターベンショナルラジオロジー学会雑誌 35 (1) 51-57 2020/08

    Publisher: (一社)日本インターベンショナルラジオロジー学会

    ISSN: 1340-4520

    eISSN: 2185-6451

  58. Development of Novel Real-Time Radiation Systems Using 4-Channel Sensors. International-journal Peer-reviewed

    Yohei Inaba, Masaaki Nakamura, Masayuki Zuguchi, Koichi Chida

    Sensors (Basel, Switzerland) 20 (9) 2020/05/11

    DOI: 10.3390/s20092741  

    More details Close

    Radiation-related tissue injuries after medical radiation procedures, such as fluoroscopically guided intervention (FGI), have been reported in patients. Real-time monitoring of medical radiation exposure administered to patients during FGI is important to avoid such tissue injuries. In our previous study, we reported a novel (prototype) real-time radiation system for FGI. However, the prototype sensor indicated low sensitivity to radiation exposure from the side and back, although it had high-quality fundamental characteristics. Therefore, we developed a novel 4-channel sensor with modified shape and size than the previous sensor, and evaluated the basic performance (i.e., measured the energy, dose linearity, dose rate, and angular dependence) of the novel and previous sensors. Both sensors of our real-time dosimeter system demonstrated the low energy dependence, excellent dose linearity (R2 = 1.0000), and good dose rate dependence (i.e., within 5% statistical difference). Besides, the sensitivity of 0° ± 180° in the horizontal and vertical directions was almost 100% sensitivity for the new sensor, which significantly improved the angular dependence. Moreover, the novel dosimeter exerted less influence on X-ray images (fluoroscopy) than other sensors because of modifying a small shape and size. Therefore, the developed dosimeter system is expected to be useful for measuring the exposure of patients to radiation doses during FGI procedures.

  59. Identification of Potential Biomarkers of Radiation Exposure in Blood Cells by Capillary Electrophoresis Time-of-Flight Mass Spectrometry. International-journal Peer-reviewed

    Lue Sun, Yohei Inaba, Norie Kanzaki, Mahesh Bekal, Koichi Chida, Takashi Moritake

    International journal of molecular sciences 21 (3) 2020/01/27

    DOI: 10.3390/ijms21030812  

    More details Close

    Biodosimetry is a useful method for estimating personal exposure doses to ionizing radiation. Studies have identified metabolites in non-cellular biofluids that can be used as markers in biodosimetry. Levels of metabolites in blood cells may reflect health status or environmental stresses differentially. Here, we report changes in the levels of murine blood cell metabolites following exposure to X-rays in vivo. Levels of blood cell metabolites were measured by capillary electrophoresis time-of-flight mass spectrometry. The levels of 100 metabolites were altered substantially following exposure. We identified 2-aminobutyric acid, 2'-deoxycytidine, and choline as potentially useful markers of radiation exposure and established a potential prediction panel of the exposure dose using stepwise regression. Levels of blood cell metabolites may be useful biomarkers in estimating exposure doses during unexpected radiation incidents.

  60. 【胸部の最新画像情報2020】心臓IVR手技における0.75mmPb当量防護眼鏡の遮蔽効果に関する臨床的検討 Peer-reviewed

    遠藤 美芽, 芳賀 喜裕, 阿部 美津也, 加賀 勇治, 大友 一輝, 村林 優樹, 稲葉 洋平, 千田 浩一

    臨床放射線 65 (1) 71-75 2020/01

    Publisher: 金原出版(株)

    ISSN: 0009-9252

  61. A phantom study to determine the optimal placement of eye dosemeters on interventional cardiology staff Peer-reviewed

    H. Ishii, K. Chida, K. Satsurai, Y. Haga, Y. Kaga, M. Abe, Y. Inaba, M. Zuguchi

    Radiation Protection Dosimetry 185 (4) 409-413 2019/12/31

    DOI: 10.1093/rpd/ncz027  

    ISSN: 0144-8420

    eISSN: 1742-3406

  62. Performance of the DOSIRIS™ eye lens dosimeter. International-journal Peer-reviewed

    Hiroki Ishii, Yoshihiro Haga, Masahiro Sota, Yohei Inaba, Koichi Chida

    Journal of radiological protection : official journal of the Society for Radiological Protection 39 (3) N19-N26 2019/09

    DOI: 10.1088/1361-6498/ab2729  

    More details Close

    Monitoring and protecting of occupational eye doses in interventional radiology (IR) are very important matters. DOSIRIS™ is the useful solution to estimate the 3 mm dose-equivalent (Hp(3)), and it can be worn behind lead glasses. And DOSIRIS™, adjustable according to 3 axes, it is ideally placed as close to the eye and in contact with the skin. So, DOSIRIS™ will be suitable eye lens dosimeter. However, the fundamental characteristics of the DOSIRIS™ in the diagnostic x-ray energy domain (including that of IR x-ray systems) remain unclear. Here, we evaluated the performance of the dosimeter in that energy range. As a result, the DOSIRIS™ has good fundamental characteristics (batch uniformity, dose linearity, energy dependence, and angular dependence) in the diagnostic x-ray energy domain. We conclude that the DOSIRIS™ has satisfactory basic performance for occupational eye dosimetry in diagnostic x-ray energy settings (including IR x-ray systems).

  63. 心血管IVRに携わるスタッフの水晶体線量評価 リアルタイム線量測定による基礎検討

    石井 浩生, 薩來 康, 芳賀 喜裕, 加賀 勇治, 阿部 美津也, 稲葉 洋平, 千田 浩一

    日本放射線技術学会東北支部雑誌 (28) 173-174 2019/01

    Publisher: (公社)日本放射線技術学会-東北支部

  64. 空間散乱X線測定による実効エネルギー変換係数の算出

    薩來 康, 石井 浩生, 千田 浩一, 稲葉 洋平, 芳賀 喜裕, 加賀 勇治

    日本放射線技術学会東北支部雑誌 (28) 233-234 2019/01

    Publisher: (公社)日本放射線技術学会-東北支部

  65. Dose-dependent decrease in anti-oxidant capacity of whole blood after irradiation: A novel potential marker for biodosimetry International-journal Peer-reviewed

    Lue Sun, Yohei Inaba, Keizo Sato, Aki Hirayama, Koji Tsuboi, Ryuji Okazaki, Koichi Chida, Takashi Moritake

    Scientific Reports 8 (1) 7425-7425 2018/12/01

    Publisher: Nature Publishing Group

    DOI: 10.1038/s41598-018-25650-y  

    ISSN: 2045-2322

    eISSN: 2045-2322

  66. Effectiveness of a novel real-time dosimeter in interventional radiology: a comparison of new and old radiation sensors. Peer-reviewed

    Yohei Inaba, Masaaki Nakamura, Koichi Chida, Masayuki Zuguchi

    Radiological physics and technology 11 (4) 445-450 2018/12

    DOI: 10.1007/s12194-018-0484-z  

    ISSN: 1865-0333

    More details Close

    Radiation dose management is important in interventional radiology (IR) procedures, such as percutaneous coronary intervention, to prevent radiation-induced injuries. Therefore, radiation dose should be monitored in real time during IR. This study evaluated the fundamental characteristics of a novel real-time skin dosimeter (RTSD) developed at our institution. In addition, we compared the performance of our new and old radiation sensors and that of a skin dose monitor (SDM), with ion chamber reference values. We evaluated the fundamental characteristics (e.g., energy dependence, dose dependence, and angular dependence) of the RTSD developed by us in the diagnostic X-ray energy range. The performance of our RTSD was similar to that of the SDM. In particular, the new radiation sensor of our RTSD demonstrated better dose rate dependence compared to the old sensor. In addition, the new sensor had the advantage of being small in size and thus minimally affecting the X-ray images compared to the old sensor. Therefore, the developed skin dosimeter and radiation sensor may be useful in real-time measurement of patients' exposure to and multi-channel monitoring of radiation in IR procedures. The new dosimeter system can be recommended for visualization and management of the radiation dose to which the patients' skin is exposed.

  67. 半導体式サーベイメータの散乱X線平均エネルギー測定精度の基礎検討 Peer-reviewed

    薩來 康, 石井 浩生, 芳賀 喜裕, 加賀 勇治, 佐藤 文貴, 本田 崇文, 稲葉 洋平, 千田 浩一

    日本放射線安全管理学会誌 17 (2) 114-120 2018/11

    Publisher: (一社)日本放射線安全管理学会

    ISSN: 1347-1503

  68. 新型半導体式サーベイメータの基本特性に関する検討 Peer-reviewed

    石井 浩生, 薩來 康, 上杉 直人, 加藤 槙子, 三戸 麻莉菜, 宮田 恒平, 稲葉 洋平, 千田 浩一

    日本放射線安全管理学会誌 17 (1) 2-8 2018/05

    Publisher: (一社)日本放射線安全管理学会

    ISSN: 1347-1503

  69. 消化管X線撮影装置用QCファントムに関する研究 Peer-reviewed

    稲葉 洋平, 加藤 守, 新田見 耕太, 森島 貴顕, 星 ちはる

    日本放射線技術学会東北部会雑誌 (27) np19-np22 2018/01

    Publisher: (公社)日本放射線技術学会-東北支部

  70. 二種類の異なる半導体式サーベイセンサの基本特性比較 Peer-reviewed

    石井 浩生, 薩來 康, 上杉 直人, 加藤 槙子, 三戸 麻莉菜, 宮田 恒平, 芳賀 喜裕, 稲葉 洋平, 千田 浩一

    東北大学医学部保健学科紀要 27 (1) 43-50 2018/01

    Publisher: 東北大学医学部保健学科

    ISSN: 1348-8899

  71. IVR-CT装置によるCT透視時の空間散乱線分布に関する基礎検討 Peer-reviewed

    本田 崇文, 佐藤 文貴, 石井 浩生, 稲葉 洋平, 常陸 真, 立花 茂, 梁川 功, 千田 浩一

    臨床放射線 62 (8) 1099-1104 2017/08

    Publisher: 金原出版(株)

    ISSN: 0009-9252

  72. Red-emission phosphor's brightness deterioration by x-ray and brightness recovery phenomenon by heating International-journal Peer-reviewed

    Masaaki Nakamura, Koichi Chida, Yohei Inaba, Ryota Kobayashi, Masayuki Zuguchi

    JOURNAL OF RADIOLOGICAL PROTECTION 37 (2) N19-N26 2017/06

    DOI: 10.1088/1361-6498/aa6272  

    ISSN: 0952-4746

    eISSN: 1361-6498

  73. リアルタイム型MOSFET線量計の基本特性評価 Peer-reviewed

    佐藤 文貴, 本田 崇文, 芳賀 喜裕, 稲葉 洋平, 加賀 勇治, 千田 浩一

    東北大学医学部保健学科紀要 26 (1) 57-65 2017/01

    Publisher: 東北大学医学部保健学科

    ISSN: 1348-8899

  74. Real-time patient radiation dosimeter for use in interventional radiology International-journal Peer-reviewed

    Koichi Chida, Mamoru Kato, Yohei Inaba, Ryota Kobayashi, Masaaki Nakamura, Yoshihisa Abe, Masayuki Zuguchi

    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS 32 (11) 1475-1478 2016/11

    DOI: 10.1016/j.ejmp.2016.10.013  

    ISSN: 1120-1797

    eISSN: 1724-191X

  75. 多施設IVR装置における実測に基づいた透視線量率の現状 DRLs 2015との乖離 Peer-reviewed

    稲葉 洋平, 小林 亮太, 千田 浩一

    日本放射線技術学会雑誌 72 (8) 689-694 2016/08

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  76. Present Situation of Fluoroscopy Radiation Doses in Many IVR Systems. Peer-reviewed

    Inaba Y, Kobayashi R, Chida K

    Nihon Hoshasen Gijutsu Gakkai zasshi 72 (8) 689-694 2016/08

    DOI: 10.6009/jjrt.2016_JSRT_72.8.689  

    ISSN: 0369-4305

    More details Close

    Japan Network for Research and Information on Medical Exposures (J-RIME) released the primary diagnostic reference levels (DRLs 2015) to optimize/manage the radiation dose for interventional radiology (IVR) on June 7, 2015 in Japan. However, this DRLs 2015 has a wide range of selection bias for only certified IVR technologists' dates. Therefore, it is important to know the radiation dose including non-certified IVR technologists' facilities. In this study, we verified the fluoroscopy radiation dose rates for many IVR systems in the present situation. This study was conducted at 13 cardiac catheterization laboratories (18 X-ray systems) around Sendai. We measured the entrance doses at the patient entrance reference point (interventional reference point) using a 20-cm-thick acrylic plate and skin-dose monitor. Although the DRLs 2015 of IVR is 20 mGy/min, the result of a fluoroscopy radiation dose in 18 X-ray systems was median (inter quartile range: IQR), 24.4 (16.3, 35.5) mGy/min. The optimization/managing the radiation dose of IVR X-ray systems is an important issue. In addition, it is necessary to intensify the activities to raise awareness for DRLs 2015.

  77. 心血管IVR装置における多施設線量比較 Peer-reviewed

    稲葉 洋平, 小林 亮太, 千田 浩一

    臨床放射線 61 (3) 483-490 2016/03

    Publisher: 金原出版(株)

    ISSN: 0009-9252

  78. A Rotatable Quality Control Phantom for Evaluating the Performance of Flat Panel Detectors in Imaging Moving Objects International-journal Peer-reviewed

    Yoshihiro Haga, Koichi Chida, Yohei Inaba, Yuji Kaga, Taiichiro Meguro, Masayuki Zuguchi

    JOURNAL OF DIGITAL IMAGING 29 (1) 38-42 2016/02

    DOI: 10.1007/s10278-015-9816-2  

    ISSN: 0897-1889

    eISSN: 1618-727X

  79. A cross-sectional study of the radiation dose and image quality of X-ray equipment used in IVR International-journal Peer-reviewed

    Yohei Inaba, Koichi Chida, Ryota Kobayashi, Masayuki Zuguchi

    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS 17 (4) 391-401 2016

    DOI: 10.1120/jacmp.v17i4.6231  

    ISSN: 1526-9914

  80. 冠動脈インターベンションにおける新型リアルタイム術者線量計システムの有用性 Peer-reviewed

    稲葉 洋平, 千田 浩一, 小林 亮太

    心臓 47 (6) 679-686 2015/06

    Publisher: (公財)日本心臓財団

    ISSN: 0586-4488

    eISSN: 2186-3016

  81. Radiation dose of cardiac IVR x-ray systems: a comparison of present and past Peer-reviewed

    Yohei Inaba, Koichi Chida, Ryota Kobayashi, Yoshihiro Haga, Masayuki Zuguchi

    ACTA CARDIOLOGICA 70 (3) 299-306 2015/06

    DOI: 10.2143/AC.70.3.3080634  

    ISSN: 0001-5385

    eISSN: 1784-973X

  82. X線出力測定器による診断用X線装置の線量測定に関する基礎検討 Peer-reviewed

    小林 亮太, 千田 浩一, 稲葉 洋平, 芳賀 喜裕, 加賀 勇治, 洞口 正之

    東北大学医学部保健学科紀要 24 (1) 39-44 2015/01

    Publisher: 東北大学医学部保健学科

    ISSN: 1348-8899

  83. 多施設におけるIVR基準点線量縦断調査 Peer-reviewed

    稲葉 洋平, 千田 浩一, 小林 亮太

    臨床放射線 59 (10) 1387-1392 2014/10

    Publisher: 金原出版(株)

    ISSN: 0009-9252

  84. Fundamental study of a real-time occupational dosimetry system for interventional radiology staff International-journal Peer-reviewed

    Yohei Inaba, Koichi Chida, Ryota Kobayashi, Yuji Kaga, Masayuki Zuguchi

    JOURNAL OF RADIOLOGICAL PROTECTION 34 (3) N65-N71 2014/09

    DOI: 10.1088/0952-4746/34/3/N65  

    ISSN: 0952-4746

    eISSN: 1361-6498

  85. CISS及びB-FFE撮影による前交通動脈穿通枝描出の試み

    稲葉 洋平, 永坂 竜男, 山中 一臣, 佐々木 博信, 千葉 陽子, 木村 智圭, 根本 整, 豊田 誠, 小川 千尋, 羽鳥 伸哉, 梁川 功, 麦倉 俊司

    日本放射線技術学会東北部会雑誌 (22) 104-105 2013/01

    Publisher: (公社)日本放射線技術学会-東北支部

  86. Physician-received scatter radiation with angiography systems used for interventional radiology: comparison among many X-ray systems Peer-reviewed

    Koichi Chida, Yoshiaki Morishima, Youhei Inaba, Masaaki Taura, Ayako Ebata, Ken Takeda, Hirotaka Shimura, Masayuki Zuguchi

    RADIATION PROTECTION DOSIMETRY 149 (4) 410-416 2012/05

    DOI: 10.1093/rpd/ncr312  

    ISSN: 0144-8420

  87. 非造影3D-TOF法を用いた穿通動脈描出の検討

    定岡 弘哲, 永坂 竜男, 山中 一臣, 佐々木 博信, 渡邊 喜久子, 木村 智圭, 稲葉 洋平, 栗田 準一郎, 豊田 誠, 杉山 周平, 梁川 功, 明石 敏昭

    日本放射線技術学会東北部会雑誌 (21) 90-91 2012/01

    Publisher: (公社)日本放射線技術学会-東北支部

  88. Comparison of dose at an interventional reference point between the displayed estimated value and measured value Peer-reviewed

    Koichi Chida, Yohei Inaba, Yoshiaki Morishima, Masaaki Taura, Ayako Ebata, Isao Yanagawa, Ken Takeda, Masayuki Zuguchi

    Radiological Physics and Technology 4 (2) 189-193 2011/07

    DOI: 10.1007/s12194-011-0121-6  

    ISSN: 1865-0333 1865-0341

  89. COMPARISON OF THE RADIATION DOSE IN A CARDIAC IVR X-RAY SYSTEM Peer-reviewed

    Youhei Inaba, Koichi Chida, Kazutoshi Shirotori, Hirotaka Shimura, Isao Yanagawa, Masayuki Zuguchi, Shoki Takahashi

    RADIATION PROTECTION DOSIMETRY 143 (1) 74-80 2011/01

    DOI: 10.1093/rpd/ncq287  

    ISSN: 0144-8420

  90. Radiation Dose of Interventional Radiology System Using a Flat-Panel Detector Peer-reviewed

    Koichi Chida, Yohei Inaba, Haruo Saito, Tadashi Ishibashi, Shoki Takahashi, Masahiro Kohzuki, Masayuki Zuguchi

    AMERICAN JOURNAL OF ROENTGENOLOGY 193 (6) 1680-1685 2009/12

    DOI: 10.2214/AJR.09.2747  

    ISSN: 0361-803X

  91. Radiation dose of the X-ray equipment used for cardiac IVR: A preliminary study. Peer-reviewed

    Inaba Y, Chida K

    Saito Ho-on Kai Museum Nat Hist Research Bulletin. 73 23-27 2009/04

  92. Evaluating the performance of a MOSFET dosimeter at diagnostic X-ray energies for interventional radiology Peer-reviewed

    Koichi Chida, Youhei Inaba, Hanako Masuyama, Isao Yanagawa, Issei Mori, Haruo Saito, Shin Maruoka, Masayuki Zuguchi

    Radiological Physics and Technology 2 (1) 58-61 2009/01

    DOI: 10.1007/s12194-008-0044-z  

    ISSN: 1865-0333

  93. Effect of Radiation Monitoring Method and Formula Differences on Estimated Physician Dose during Percutaneous Coronary Intervention Peer-reviewed

    K. Chida, Y. Morishima, H. Masuyama, H. Chiba, Y. Katahira, Y. Inaba, I. Mori, S. Maruoka, S. Takahashi, M. Kohzuki, M. Zuguchi

    ACTA RADIOLOGICA 50 (2) 170-173 2009

    DOI: 10.1080/02841850802616745  

    ISSN: 0284-1851

  94. Is the MOSFET dosimeter feasible at diagnostic X-ray energies for interventional radiology?

    K. Chida, Y. Inaba, I. Yanagawa, H. Saito, T. Ishibashi, M. Zuguchi

    IFMBE Proceedings 25 (3) 1-2 2009

    DOI: 10.1007/978-3-642-03902-7-1  

    ISSN: 1680-0737

  95. Comparison of scattered radiation in a cardiac IVR X-ray system Peer-reviewed

    稲葉 洋平, 江端 綾子, 田浦 将明, 結城 裕子, 竹川 弥香, 梁川 功, 田村 元, 町田 好男, 小倉 隆英, 森 一生, 本間 経康, 石橋 忠司, 齋藤 春夫, 高井 良尋, 佐藤 行彦, 仲田 栄子, 丸岡 伸, 細貝 良行, 千田 浩一

    Bulletin of School of Health Sciences, Tohoku University 18 (1) 45-51 2009

    Publisher: 東北大学医学部保健学科

    ISSN: 1348-8899

  96. Usefulness of non-lead aprons in radiation protection for physicians performing interventional procedures Peer-reviewed

    Masayuki Zuguchi, Koichi Chida, Masaaki Taura, Yohei Inaba, Ayako Ebata, Shogo Yamada

    RADIATION PROTECTION DOSIMETRY 131 (4) 531-534 2008/09

    DOI: 10.1093/rpd/ncn244  

    ISSN: 0144-8420

Show all ︎Show first 5

Misc. 119

  1. Cアーム式透視装置を用いたERCP従事者のための放射線防護衝立の開発

    石井 浩生, 稲葉 洋平, 千田 浩一, 小野寺 崇, 斎 政博

    日本放射線技術学会総会学術大会予稿集 80回 197-198 2024/03

    Publisher: (公社)日本放射線技術学会

    ISSN: 1884-7846

  2. Cアーム式透視装置を用いたERCP従事者のための放射線防護衝立の開発

    石井 浩生, 稲葉 洋平, 千田 浩一, 小野寺 崇, 斎 政博

    日本放射線技術学会総会学術大会予稿集 80回 197-198 2024/03

    Publisher: (公社)日本放射線技術学会

    ISSN: 1884-7846

  3. シンチレータ式簡易測定器の諸特性に関する基礎検討

    礒部 理央, 古川 未来, 大野 紗耶, 進藤 遼太, 山本 啓介, 稲葉 洋平, 鈴木 正敏, 千田 浩一

    日本放射線安全管理学会誌 22 (2) 72-82 2023/11

    Publisher: (一社)日本放射線安全管理学会

    ISSN: 1347-1503

  4. IVR従事者の頭部から発生する後方散乱線が自身の水晶体被ばく線量に及ぼす影響

    大野 紗耶, 今田 聡恵, 進藤 僚太, 山本 啓介, 稲葉 洋平, 千田 浩一

    日本放射線技術学会雑誌 79 (9) 1013-1014 2023/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  5. ERCPにおけるCアーム式透視装置用放射線防護衝立の試作および基礎検討

    石井 浩生, 稲葉 洋平, 千田 浩一, 小野寺 崇, 斎 政博

    日本放射線技術学会雑誌 79 (9) 1016-1017 2023/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  6. 電子式積算線量計の校正前後評価

    岡部 優輝, 秋澤 彩乃, 和泉 哉汰, 佐々木 永仁, 米永 裕敬, 稲葉 洋平, 千田 浩一

    日本放射線技術学会雑誌 79 (9) 1068-1068 2023/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  7. 高感度半導体式電子ポケット線量計の基本性能評価

    秋澤 彩乃, 和泉 哉汰, 岡部 優輝, 佐々木 永仁, 米永 裕敬, 稲葉 洋平, 千田 浩一

    日本放射線技術学会雑誌 79 (9) 1068-1068 2023/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  8. β線用プラスチックシンチレーションサーベイメータの性能評価 線源検出器間距離が検出能に与える影響

    山本 啓介, 礒部 理央, 大野 紗耶, 今田 聡恵, 進藤 僚太, 稲葉 洋平, 細井 義夫, 千田 浩一

    日本放射線技術学会雑誌 79 (9) 1068-1069 2023/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  9. 宿泊療養施設におけるCovid-19患者のポータブルX線撮影で生じる空間散乱線測定 胸部ファントムを用いた検討

    藤沢 昌輝, 稲葉 洋平, 山田 歩実, 加藤 聖規, 服部 兼進, 小野寺 保, 千田 浩一

    日本放射線技術学会雑誌 79 (9) 1069-1070 2023/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  10. ハイブリッドERにおける透視手技時の人体ファントムを用いた空間散乱線分布

    大森 悠斗, 古川 未来, 小野 勝範, 稲葉 洋平

    日本放射線技術学会雑誌 79 (9) 1101-1101 2023/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  11. CR及びFPDシステム使用時におけるポータブルX線撮影従事者の水晶体被ばく線量の比較

    今田 聡恵, 芳賀 喜裕, 大友 一輝, 曽田 真宏, 阿部 美津也, 加賀 勇治, 稲葉 洋平, 千田 浩一

    日本放射線技術学会雑誌 79 (9) 1103-1103 2023/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  12. IVR従事者の頭部から発生する後方散乱線が自身の水晶体被ばく線量に及ぼす影響

    大野 紗耶, 今田 聡恵, 進藤 僚太, 山本 啓介, 稲葉 洋平, 千田 浩一

    日本放射線技術学会雑誌 79 (9) 1013-1014 2023/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  13. ERCPにおけるCアーム式透視装置用放射線防護衝立の試作および基礎検討

    石井 浩生, 稲葉 洋平, 千田 浩一, 小野寺 崇, 斎 政博

    日本放射線技術学会雑誌 79 (9) 1016-1017 2023/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  14. 電子式積算線量計の校正前後評価

    岡部 優輝, 秋澤 彩乃, 和泉 哉汰, 佐々木 永仁, 米永 裕敬, 稲葉 洋平, 千田 浩一

    日本放射線技術学会雑誌 79 (9) 1068-1068 2023/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  15. 高感度半導体式電子ポケット線量計の基本性能評価

    秋澤 彩乃, 和泉 哉汰, 岡部 優輝, 佐々木 永仁, 米永 裕敬, 稲葉 洋平, 千田 浩一

    日本放射線技術学会雑誌 79 (9) 1068-1068 2023/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  16. β線用プラスチックシンチレーションサーベイメータの性能評価 線源検出器間距離が検出能に与える影響

    山本 啓介, 礒部 理央, 大野 紗耶, 今田 聡恵, 進藤 僚太, 稲葉 洋平, 細井 義夫, 千田 浩一

    日本放射線技術学会雑誌 79 (9) 1068-1069 2023/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  17. 宿泊療養施設におけるCovid-19患者のポータブルX線撮影で生じる空間散乱線測定 胸部ファントムを用いた検討

    藤沢 昌輝, 稲葉 洋平, 山田 歩実, 加藤 聖規, 服部 兼進, 小野寺 保, 千田 浩一

    日本放射線技術学会雑誌 79 (9) 1069-1070 2023/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  18. ハイブリッドERにおける透視手技時の人体ファントムを用いた空間散乱線分布

    大森 悠斗, 古川 未来, 小野 勝範, 稲葉 洋平

    日本放射線技術学会雑誌 79 (9) 1101-1101 2023/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  19. CR及びFPDシステム使用時におけるポータブルX線撮影従事者の水晶体被ばく線量の比較

    今田 聡恵, 芳賀 喜裕, 大友 一輝, 曽田 真宏, 阿部 美津也, 加賀 勇治, 稲葉 洋平, 千田 浩一

    日本放射線技術学会雑誌 79 (9) 1103-1103 2023/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  20. 被ばく防護の実際と実践 水晶体被ばく線量のリアルタイム解析について

    加藤 聖規, 藤沢 昌輝, 服部 兼進, 山田 歩実, 芳賀 喜裕, 加賀 勇治, 阿部 美津也, 稲葉 洋平, 千田 浩一

    日本放射線技術学会東北支部雑誌 (32) np55-np56 2023/02

    Publisher: (公社)日本放射線技術学会-東北支部

  21. 指定箇所検査用放射能汚染モニタのバックグラウンド測定等の基礎検討

    中村 美緒, 佐藤 拓, 鈴木 華衣, 田辺 真子, 千葉 由梨乃, 菅野 典子, 越智 隆浩, 阿部 喜弘, 稲葉 洋平, 千田 浩一

    日本放射線技術学会東北支部雑誌 (32) np183-np184 2023/02

    Publisher: (公社)日本放射線技術学会-東北支部

  22. 心臓・血管系IVR看護師の長期間測定による水晶体被ばく線量評価に関する検討

    山田 歩実, 芳賀 喜裕, 曽田 真宏, 加賀 勇治, 阿部 美津也, 稲葉 洋平, 千田 浩一

    日本放射線技術学会雑誌 78 (9) 1035-1035 2022/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  23. 機能補償型γ線用シンチレーション式サーベイメータの温度依存性に関する評価

    礒部 理央, 大野 紗耶, 今田 聡恵, 進藤 僚太, 山本 啓介, 稲葉 洋平, 千田 浩一

    日本放射線技術学会雑誌 78 (9) 1047-1047 2022/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  24. β線用サーベイメータの基礎的検討 プラスチックシンチレーションサーベイメータとGMサーベイメータの比較

    山本 啓介, 礒部 理央, 大野 紗耶, 今田 聡恵, 進藤 僚太, 稲葉 洋平, 千田 浩一

    日本放射線技術学会雑誌 78 (9) 1047-1047 2022/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  25. 災害時用ポータブルX線発生装置のシステム開発

    加藤 聖規, 藤沢 昌輝, 村林 優樹, 稲葉 洋平, 千田 浩一

    日本放射線技術学会雑誌 78 (9) 1059-1059 2022/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  26. ポータブルX線撮影時における従事者の水晶体被ばくに関する検討 臨床データを用いた研究

    今田 聡恵, 大友 一輝, 芳賀 善裕, 曽田 真宏, 阿部 美津也, 加賀 勇治, 稲葉 洋平, 千田 浩一

    日本放射線技術学会雑誌 78 (9) 1063-1063 2022/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  27. 低線量・低線量率放射線の長期被ばくによる肝臓の酸化ストレス状態の変動

    石川 諒椰, 鈴木 正敏, 木野 康志, 遠藤 暁, 稲葉 洋平, 福本 学, 千田 浩一

    日本放射線技術学会雑誌 78 (9) 1104-1104 2022/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  28. 従事者被ばく測定用新型リアルタイム線量計の電波特性

    服部 兼進, 加藤 聖規, 藤沢 昌輝, 山田 歩実, 稲葉 洋平, 芳賀 喜裕, 阿部 美津也, 千田 浩一

    日本放射線技術学会雑誌 78 (9) 1105-1105 2022/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  29. ERCPにおける基準空気カーマと入射表面空気カーマの乖離に関する基礎的検討

    石井 浩生, 安部 圭亮, 稲葉 洋平, 石塚 真澄, 坂本 博, 千田 浩一

    日本放射線技術学会総会学術大会予稿集 78回 231-231 2022/03

    Publisher: (公社)日本放射線技術学会

    ISSN: 1884-7846

  30. ERCPにおける基準空気カーマと入射表面空気カーマの乖離に関する基礎的検討

    石井 浩生, 安部 圭亮, 稲葉 洋平, 石塚 真澄, 坂本 博, 千田 浩一

    日本放射線技術学会総会学術大会予稿集 78回 231-231 2022/03

    Publisher: (公社)日本放射線技術学会

    ISSN: 1884-7846

  31. 宮城県COVID-19軽症者療養施設における課題とその解決 東日本大震災の経験をパンデミックに生かす

    有田 龍太郎, 小野 理恵, 高山 真, 小野寺 保, 中村 直毅, 稲葉 洋平, 阿部 喜子, 中山 雅晴, 石井 正

    日本救急医学会雑誌 32 (12) 1374-1374 2021/11

    Publisher: (一社)日本救急医学会

    ISSN: 0915-924X

    eISSN: 1883-3772

  32. シンチレーションサーベイメータの温度特性に関する基礎的検討

    古川 未来, 礒部 理央, 大野 紗耶, 郷内 優作, 進藤 僚太, 山本 啓介, 稲葉 洋平, 千田 浩一

    日本放射線技術学会雑誌 77 (9) 1119-1119 2021/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  33. 新型ハイブリッドサーベイメータの基本的性能評価 X線検査室等の空間散乱線測定に関する検討

    大森 悠斗, 巻 周星, 石沢 祥子, 川口 和奏, 山田 芙美佳, 稲葉 洋平, 千田 浩一

    日本放射線技術学会雑誌 77 (9) 1119-1119 2021/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  34. 新しい医療スタッフ用リアルタイム被ばくモニタリングシステムの基礎的性能評価

    服部 兼進, 加藤 聖規, 藤沢 昌輝, 安野 ひかる, 山田 歩実, 稲葉 洋平, 千田 浩一

    日本放射線技術学会雑誌 77 (9) 1121-1121 2021/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  35. シンチレーションサーベイメータの温度特性に関する基礎的検討

    古川 未来, 礒部 理央, 大野 紗耶, 郷内 優作, 進藤 僚太, 山本 啓介, 稲葉 洋平, 千田 浩一

    日本放射線技術学会雑誌 77 (9) 1119-1119 2021/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  36. 新型ハイブリッドサーベイメータの基本的性能評価 X線検査室等の空間散乱線測定に関する検討

    大森 悠斗, 巻 周星, 石沢 祥子, 川口 和奏, 山田 芙美佳, 稲葉 洋平, 千田 浩一

    日本放射線技術学会雑誌 77 (9) 1119-1119 2021/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  37. 新しい医療スタッフ用リアルタイム被ばくモニタリングシステムの基礎的性能評価

    服部 兼進, 加藤 聖規, 藤沢 昌輝, 安野 ひかる, 山田 歩実, 稲葉 洋平, 千田 浩一

    日本放射線技術学会雑誌 77 (9) 1121-1121 2021/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  38. 経皮的心血管インターベンションにおける治療区域別の手技線量とDRLs 2020の比較

    増渕 裕介, 千田 浩一, 稲葉 洋平, 嶋田 涼香, 山下 明, 景山 倫也, 水沼 仁孝

    日本インターベンショナルラジオロジー学会雑誌 36 (Suppl.) 188-188 2021/04

    Publisher: (一社)日本インターベンショナルラジオロジー学会

    ISSN: 1340-4520

    eISSN: 2185-6451

  39. ドライブスルー型新型コロナウイルス感染症検査外来の運用 検査診療体制について

    稲葉 洋平, 阿部 喜子, 西岡 貴志, 藤田 基生, 石井 正

    Japanese Journal of Disaster Medicine 25 (3) 165-165 2021/03

    Publisher: (一社)日本災害医学会

    ISSN: 2189-4035

    eISSN: 2434-4214

  40. ドライブスルー型新型コロナウイルス感染症検査外来の運用 ロジスティクスについて

    阿部 喜子, 稲葉 洋平, 西岡 貴志, 藤田 基生, 石井 正

    Japanese Journal of Disaster Medicine 25 (3) 166-166 2021/03

    Publisher: (一社)日本災害医学会

    ISSN: 2189-4035

    eISSN: 2434-4214

  41. COVID-19軽症者療養施設医療対応のための検査体制とその有用性

    高山真, 小野理恵, 有田龍太郎, 齊藤奈津美, 鈴木聡子, 只野恭教, 赤石哲也, 田中淳一, 菅野武, 菊地章子, 大澤稔, 小野寺浩, 阿部倫明, 井戸敬介, 稲葉洋平, 中村直毅, 中山雅晴, 石井正

    日本病院総合診療医学会雑誌(Web) 17 (臨増2) 178-178 2021

    Publisher: (一社)日本病院総合診療医学会

    ISSN: 2185-8136

    eISSN: 2758-7878

  42. 生物学的線量推定の新技術 被ばく後の血液抗酸化能変化(Novel technics for biodosimetry Dose-dependent decrease in antioxidant capacity of blood after irradiation: A novel potential marker for biodosimetry)

    孫 略, 稲葉 洋平, 千田 浩一, 盛武 敬

    日本放射線影響学会大会講演要旨集 63回 50-50 2020/10

    Publisher: (一社)日本放射線影響学会

    ISSN: 1347-8680

  43. 福島原発事故による周辺生物への影響調査研究 福島原発事故による動物・環境試料を用いた放射線被ばく影響解析(Radiation effects on non-human biota after the Fukushima nuclear power plant accident Comprehensive analysis of radiation effects using disaster affected animal and environmental samples of Fukushima Dai-ichi nuclear power plant accident)

    鈴木 正敏, 遠藤 暁, 松谷 祐輝, 岡 壽崇, 小野 拓実, 光安 優典, 木野 康志, 高橋 温, 篠田 壽, 漆原 佑介, 中島 裕夫, 二宮 和彦, 三浦 富智, 稲葉 洋平, 千田 浩一, 福本 学

    日本放射線影響学会大会講演要旨集 63回 38-38 2020/10

    Publisher: (一社)日本放射線影響学会

    ISSN: 1347-8680

  44. 胃X線透視検査における被検者被曝線量の推定は可能か?

    稲葉 洋平, 渡邉 晃成, 板橋 裕禎, 松田 夏枝, 宍戸 玲奈, 藤原 実

    日本消化器がん検診学会雑誌 58 (Suppl総会) 551-551 2020/09

    Publisher: (一社)日本消化器がん検診学会

    ISSN: 1880-7666

    eISSN: 2185-1190

  45. 3mm線量当量線量計を用いたCT透視下生検における水晶体被曝線量の実測

    稲葉 洋平, 大友 一輝, 遠藤 美芽, 村林 優樹, 常陸 真, 綿貫 宗則, 千田 浩一

    日本インターベンショナルラジオロジー学会雑誌 35 (Suppl.) 240-240 2020/08

    Publisher: (一社)日本インターベンショナルラジオロジー学会

    ISSN: 1340-4520

    eISSN: 2185-6451

  46. ポータブルX線撮影における放射線技師の被曝防護意識に関する調査

    大友 一輝, 遠藤 美芽, 村林 優樹, 安部 圭亮, 小野寺 真奈, 鈴木 友裕, 高橋 拓己, 一ツ木 康晶, 稲葉 洋平, 千田 浩一

    日本放射線安全管理学会誌 19 (1) 2-10 2020/06

    Publisher: (一社)日本放射線安全管理学会

    ISSN: 1347-1503

  47. 新型0.07mm鉛当量防護眼鏡のIVR臨床における基礎的検討

    遠藤 美芽, 大友 一輝, 村林 優樹, 芳賀 喜裕, 阿部 美津也, 加賀 勇治, 稲葉 洋平, 千田 浩一

    日本保健物理学会研究発表会講演要旨集 53回 58-58 2020/06

    Publisher: (一社)日本保健物理学会

  48. 診療放射線技師の被曝防護の実態調査 ポータブルX線撮影に関するアンケートによる検討

    大友 一輝, 遠藤 美芽, 村林 優樹, 安部 圭亮, 小野寺 真奈, 鈴木 友裕, 高橋 拓己, 一ツ木 康晶, 稲葉 洋平, 千田 浩一

    日本保健物理学会研究発表会講演要旨集 53回 61-61 2020/06

    Publisher: (一社)日本保健物理学会

  49. 空間散乱線量の測定に関する基礎検討 種々のファントムによる比較検討

    巻 周星, 石沢 祥子, 大森 悠斗, 川口 和奏, 山田 芙美佳, 大友 一輝, 芳賀 喜裕, 阿部 美津也, 加賀 勇治, 千田 浩一, 稲葉 洋平

    日本放射線技術学会東北支部雑誌 (29) 180-181 2020/01

    Publisher: (公社)日本放射線技術学会-東北支部

  50. 無線通信機能付きリアルタイム患者被曝線量計の試作

    石沢 祥子, 巻 周星, 山田 芙美佳, 川口 和奏, 大森 悠斗, 村林 優樹, 大友 一輝, 遠藤 美芽, 芳賀 喜裕, 稲葉 洋平, 千田 浩一

    日本放射線技術学会東北支部雑誌 (29) 182-183 2020/01

    Publisher: (公社)日本放射線技術学会-東北支部

  51. 口内法X線撮影時における空間散乱線量分布の基礎的評価

    西原 拓也, 高根 侑美, 鈴木 友裕, 石塚 真澄, 小野 勝範, 稲葉 洋平

    日本放射線技術学会東北支部雑誌 (29) 245-246 2020/01

    Publisher: (公社)日本放射線技術学会-東北支部

  52. 小児の口内法X線撮影における撮影者の介助被ばく

    鈴木 友裕, 高根 侑美, 西原 拓也, 石塚 真澄, 小野 勝範, 稲葉 洋平

    日本放射線技術学会東北支部雑誌 (29) 247-248 2020/01

    Publisher: (公社)日本放射線技術学会-東北支部

  53. 直接胃X線透視検査の放射線被ばく線量と身体測定データの相関について

    根本 まなみ, 稲葉 洋平, 熊田 祐也, 千田 浩一

    総合健診 47 (1) 235-235 2020/01

    Publisher: (一社)日本総合健診医学会

    ISSN: 1347-0086

  54. 胃X線透視検査におけるBody Mass Indexを利用した被ばく線量の推定

    渡邉 晃成, 稲葉 洋平, 板橋 裕禎, 藤原 実, 松田 夏枝, 宍戸 玲奈, 石川 智美, 池田 有花

    日本放射線技術学会雑誌 75 (9) 969-970 2019/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  55. 胃X線透視検査の被ばく線量と身体測定データの関連調査

    板橋 裕禎, 稲葉 洋平, 渡邉 晃成, 藤原 実, 松田 夏枝, 宍戸 玲奈, 石川 智美, 池田 有花

    日本放射線技術学会雑誌 75 (9) 970-970 2019/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  56. 血管造影IVRにおける空間散乱線量等の測定評価 ファントム実験による基礎検討

    大森 悠斗, 巻 周星, 大友 一輝, 芳賀 善裕, 稲葉 洋平, 加賀 勇治, 阿部 美津也, 千田 浩一

    日本放射線技術学会雑誌 75 (9) 993-993 2019/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  57. 0.75mm鉛当量防護眼鏡による水晶体等価線量の低減に関する臨床的検討

    遠藤 美芽, 芳賀 喜裕, 阿部 美津也, 加賀 勇治, 大友 一輝, 村林 優樹, 稲葉 洋平, 千田 浩一

    日本放射線技術学会雑誌 75 (9) 1026-1026 2019/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  58. 歯科用ポータブルX線撮影における空間線量分布の評価

    高根 侑美, 稲葉 洋平, 鈴木 友裕, 西原 拓也, 石塚 真澄, 小野 勝範

    日本放射線技術学会雑誌 75 (9) 1051-1051 2019/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  59. 高校生における放射線に関する知識の特徴と放射線防護へ向けた教育

    大葉 隆, 稲葉 洋平, 津山 尚宏, 坪倉 正治, 村上 道夫, 千田 浩一, 大津留 晶

    JART: 日本診療放射線技師会誌 66 (9) 988-988 2019/09

    Publisher: (公社)日本診療放射線技師会

    ISSN: 2187-2538

  60. 高分解能コーンビームCTにおける画質、放射線量、および金属アーチファクト低減の評価(Evaluation of Image Quality, Radiation Dose and Metal Artifact Reduction in High Resolution Cone Beam CT)

    Takeuchi Takashi, Takano Hirokazu, Hatori Shinya, Inaba Yohei

    日本放射線技術学会総会学術大会予稿集 75回 297-297 2019/03

    Publisher: (公社)日本放射線技術学会

    ISSN: 1884-7846

  61. 心血管IVRに携わるスタッフの水晶体線量評価 リアルタイム線量測定による基礎検討

    石井 浩生, 薩來 康, 芳賀 喜裕, 加賀 勇治, 阿部 美津也, 稲葉 洋平, 千田 浩一

    日本放射線技術学会東北部会雑誌 (28) 173-174 2019/01

    Publisher: (公社)日本放射線技術学会-東北支部

  62. 空間散乱X線測定による実効エネルギー変換係数の算出

    薩來 康, 石井 浩生, 千田 浩一, 稲葉 洋平, 芳賀 喜裕, 加賀 勇治

    日本放射線技術学会東北部会雑誌 (28) 233-234 2019/01

    Publisher: (公社)日本放射線技術学会-東北支部

  63. MRIの設置および利用状況調査

    佐藤 美帆, 別所 俊一郎, 稲葉 洋平, 町田 好男, 高瀬 圭

    日本放射線技術学会雑誌 74 (9) 976-976 2018/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  64. IVRに従事するスタッフの水晶体線量計着用部位に関する基礎検討

    石井 浩生, 薩來 康, 芳賀 喜裕, 加賀 勇治, 阿部 美津也, 稲葉 洋平, 千田 浩一

    日本放射線技術学会雑誌 74 (9) 1095-1095 2018/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  65. 空間散乱X線のエネルギー測定による放射線防護眼鏡の鉛当量厚の検討

    薩來 康, 石井 浩生, 芳賀 喜裕, 加賀 勇治, 佐藤 文貴, 本田 崇文, 稲葉 洋平, 千田 浩一

    日本放射線技術学会雑誌 74 (9) 1096-1096 2018/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  66. 診断領域エネルギにおける水晶体職業被ばく測定用線量計の基本特性評価 安定性およびFadingに関する検討

    田辺 ゆうき, 田母神 陽, 菅原 拓巳, 石井 浩生, 芳賀 喜裕, 稲葉 洋平, 加賀 勇治, 千田 浩一

    日本放射線技術学会雑誌 74 (9) 1096-1096 2018/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  67. ポータブル撮影における空間散乱線量評価に関する基礎検討

    大友 一輝, 有馬 悠貴, 齊藤 新, 芳賀 喜裕, 阿部 美津也, 加賀 勇治, 稲葉 洋平, 千田 浩一

    日本放射線技術学会雑誌 74 (9) 1100-1100 2018/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  68. 血管造影・IVRに携わる医療従事者の水晶体線量の左右差に関する基礎検討

    石井 浩生, 薩來 康, 佐藤 文貴, 本田 崇文, 芳賀 喜裕, 加賀 勇治, 稲葉 洋平, 千田 浩一

    日本保健物理学会研究発表会講演要旨集 51回 53-53 2018/06

    Publisher: (一社)日本保健物理学会

  69. 水晶体被ばく防護における基礎検討 空間散乱X線平均エネルギー測定の検討

    薩來 康, 石井 浩生, 本田 崇文, 佐藤 文貴, 稲葉 洋平, 千田 浩一

    日本保健物理学会研究発表会講演要旨集 51回 59-59 2018/06

    Publisher: (一社)日本保健物理学会

  70. マルチチャネルリアルタイムモニタを用いた新規放射線量計の有用性(Usefulness of Novel Radiation Dosimeter Using a Multi-channel Real-time Monitor)

    Inaba Yohei, Ishii Hiroki, Satsurai Ko, Haga Yoshihiro, Chida Koichi

    日本放射線技術学会総会学術大会予稿集 74回 304-304 2018/03

    Publisher: (公社)日本放射線技術学会

    ISSN: 1884-7846

  71. Changes in blood antioxidant capacity after irradiation: A novel biodosimetry method

    盛武敬, SUN Lue, 稲葉洋平, 千田浩一

    電子スピンサイエンス学会年会講演要旨集 57th 2018

  72. 天吊り防護板による従事者被曝線量の防護効果検証

    一ツ木 康晶, 安部 圭亮, 小野寺 真奈, 鈴木 友裕, 高橋 拓己, 稲葉 洋平, 千田 浩一, 佐藤 文貴, 本田 崇文, 石井 浩生, 薩來 康, 立花 茂, 島田 一生, 杉山 周平

    日本放射線技術学会東北部会雑誌 (27) np135-np136 2018/01

    Publisher: (公社)日本放射線技術学会-東北支部

  73. 水晶体線量計の3mm線量当量測定に関する基礎的検討 70μm線量当量および1cm線量当量との比較

    高橋 拓己, 安部 圭亮, 小野寺 真奈, 鈴木 友裕, 一ツ木 康昌, 石井 浩生, 薩來 康, 上杉 直人, 加藤 槙子, 三戸 麻莉菜, 芳賀 喜裕, 阿部 美津也, 加賀 勇治, 稲葉 洋平, 千田 浩一, 大口 裕之

    日本放射線技術学会東北部会雑誌 (27) np137-np138 2018/01

    Publisher: (公社)日本放射線技術学会-東北支部

  74. 水晶体被ばく線量計の基本的性能評価に関する基礎検討

    安部 圭亮, 小野寺 真奈, 鈴木 友裕, 高橋 拓己, 一ツ木 康晶, 石井 浩生, 薩來 康, 本田 崇文, 稲葉 洋平, 佐藤 文貴, 千田 浩一, 芳賀 喜裕, 阿部 美津也, 加賀 勇治, 狩野 好延

    日本放射線技術学会東北部会雑誌 (27) np139-np140 2018/01

    Publisher: (公社)日本放射線技術学会-東北支部

  75. 新型半導体式サーベイメータの空間散乱X線平均エネルギー測定精度評価

    薩來 康, 石井 浩生, 本田 崇文, 千田 浩一, 稲葉 洋平, 佐藤 文貴, 宮田 恒平, 三戸 麻莉菜

    日本放射線技術学会東北部会雑誌 (27) np145-np146 2018/01

    Publisher: (公社)日本放射線技術学会-東北支部

  76. CTガイド下生検における医療スタッフの被曝線量の実測 動画を用いた分析

    本田 崇文, 石井 浩生, 薩來 康, 佐藤 文貴, 稲葉 洋平, 千田 浩一, 立花 茂, 常陸 真

    日本放射線技術学会東北部会雑誌 (27) np199-np200 2018/01

    Publisher: (公社)日本放射線技術学会-東北支部

  77. 血管造影・IVRに携わる医療スタッフの水晶体線量の左右差に関する基礎的検討

    石井 浩生, 薩來 康, 本田 崇文, 佐藤 文貴, 稲葉 洋平, 千田 浩一, 上杉 直人, 加藤 槙子, 芳賀 喜裕, 加賀 勇治

    日本放射線技術学会東北部会雑誌 (27) np239-np240 2018/01

    Publisher: (公社)日本放射線技術学会-東北支部

  78. IVRに従事する医師・看護師における左右の水晶体線量についての検討

    佐藤 文貴, 稲葉 洋平, 千田 浩一, 本田 崇文, 芳賀 喜裕, 加賀 勇治

    日本放射線技術学会東北部会雑誌 (27) np241-np242 2018/01

    Publisher: (公社)日本放射線技術学会-東北支部

  79. 電子スピン共鳴法を用いた被ばく後の酸化ストレスレベルの測定

    孫 略, 稲葉 洋平, 佐藤 圭創, 平山 暁, 坪井 康次, 千田 浩一, 盛武 敬

    日本放射線影響学会大会講演要旨集 60回 117-117 2017/10

    Publisher: (一社)日本放射線影響学会

    ISSN: 1347-8680

  80. PCI及びPercutaneous Peripheral Intervention(PPI)に従事する医師における水晶体被ばく線量の左右差についての初期的検討

    佐藤 文貴, 本田 崇文, 芳賀 喜裕, 石井 浩生, 薩來 康, 稲葉 洋平, 加賀 勇治, 千田 浩一

    日本放射線技術学会雑誌 73 (9) 841-841 2017/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  81. IVR装置における患者照射基準点線量の測定及び線量表示値との比較

    本田 崇文, 佐藤 文貴, 石井 浩生, 薩來 康, 稲葉 洋平, 立花 茂, 加賀 勇治, 千田 浩一

    日本放射線技術学会雑誌 73 (9) 912-912 2017/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  82. 新型半導体式サーベイメータの基礎検討 散乱X線平均エネルギー測定精度の検討

    薩來 康, 石井 浩生, 佐藤 文貴, 本田 崇文, 稲葉 洋平, 千田 浩一, 宮田 恒平, 三戸 麻莉菜

    日本放射線技術学会雑誌 73 (9) 914-914 2017/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  83. IVR装置間における患者照射基準点線量測定から見えてきた実測の重要性

    稲葉 洋平, 本田 崇文, 佐藤 文貴, 芳賀 喜裕, 千田 浩一

    IVR: Interventional Radiology 32 (Suppl.) 260-260 2017/04

    Publisher: (一社)日本インターベンショナルラジオロジー学会

    ISSN: 1340-4520

    eISSN: 2185-6451

  84. マルチチャネルリアルタイムモニタを用いた新規の放射線線量計に関する基礎研究(Fundamental Study of a Novel Radiation Dosimeter Using a Multi-Channel Real-Time Monitor)

    Inaba Yohei, Honda Takfumi, Sato Fumitaka, Chida Koichi, Haga Yoshihiro, Kaga Yuji

    日本放射線技術学会総会学術大会予稿集 73回 288-288 2017/03

    Publisher: (公社)日本放射線技術学会

    ISSN: 1884-7846

  85. 英語発表のポイントとコツ 若手会員に向けるメッセージ

    稲葉 洋平

    日本放射線技術学会総会学術大会予稿集 73回 119-119 2017/03

    Publisher: (公社)日本放射線技術学会

    ISSN: 1884-7846

  86. Changes in blood antioxidant capacity after irradiation: A novel biodosimetry method

    SUN Lue, SUN Lue, 稲葉洋平, 佐藤圭創, 平山暁, 千田浩一, 盛武敬

    電子スピンサイエンス学会年会講演要旨集 56th 2017

  87. 心血管IVR装置間における患者照射基準点線量の実測と線量表示値の比較

    上杉 直人, 石井 浩生, 宮田 恒平, 加藤 槙子, 三戸 麻莉菜, 稲葉 洋平, 千田 浩一

    日本放射線技術学会東北部会雑誌 (26) np178-np179 2017/01

    Publisher: (公社)日本放射線技術学会-東北支部

  88. 新型半導体式サーベイメータの基本特性評価

    宮田 恒平, 石井 浩生, 三戸 麻莉菜, 加藤 槙子, 上杉 直人, 千田 浩一, 稲葉 洋平, 本田 崇文, 佐藤 文貴, 斎 政博, 加賀 勇治, 芳賀 喜裕

    日本放射線技術学会東北部会雑誌 (26) np190-np191 2017/01

    Publisher: (公社)日本放射線技術学会-東北支部

  89. 血管造影・IVRに従事する医師、看護師の被曝線量の検討

    佐藤 文貴, 稲葉 洋平, 千田 浩一, 本田 崇文, 片岡 望, 熊坂 江里子, 芳賀 喜裕, 阿部 美津也, 加賀 勇治

    日本放射線技術学会東北部会雑誌 (26) np194-np194 2017/01

    Publisher: (公社)日本放射線技術学会-東北支部

  90. CT透視下生検における術者被曝線量計の位置に関する検討

    本田 崇文, 佐藤 文貴, 稲葉 洋平, 千田 浩一, 常陸 真

    日本放射線技術学会東北部会雑誌 (26) np198-np199 2017/01

    Publisher: (公社)日本放射線技術学会-東北支部

  91. 半導体センサを使用した新しいサーベイメータの基礎検討

    石井 浩生, 宮田 恒平, 三戸 麻莉菜, 加藤 槙子, 佐藤 文貴, 本田 崇文, 稲葉 洋平, 千田 浩一

    日本放射線技術学会雑誌 72 (9) 841-842 2016/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  92. センサーの違いによるリアルタイム型MOSFET線量計の基本特性評価

    佐藤 文貴, 千田 浩一, 稲葉 洋平, 本田 崇文, 芳賀 喜裕, 加賀 勇治, 上杉 直人

    日本放射線技術学会雑誌 72 (9) 842-842 2016/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  93. X線CT透視時のX線CT装置間での空間散乱線分布の比較 ファントム実験

    本田 崇文, 稲葉 洋平, 千田 浩一, 川畑 朋桂, 森 隆一, 佐藤 文貴, 立花 茂, 梁川 功

    日本放射線技術学会雑誌 72 (9) 860-860 2016/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  94. CT透視下生検における従事者被曝線量の実測

    稲葉 洋平, 千田 浩一, 常陸 真, 綿貫 宗則

    IVR: Interventional Radiology 31 (Suppl.) 302-302 2016/04

    Publisher: (一社)日本インターベンショナルラジオロジー学会

    ISSN: 1340-4520

    eISSN: 2185-6451

  95. 多施設心血管IVR装置における患者照射基準点線量の実測 DRLs2015との考察

    稲葉 洋平, 千田 浩一, 小林 亮太, 梁川 功, 加賀 勇治

    日本放射線技術学会総会学術大会予稿集 72回 241-241 2016/02

    Publisher: (公社)日本放射線技術学会

    ISSN: 1884-7846

  96. MRIの保有状況と利用に関する全国調査

    佐藤 美帆, 町田 好男, 別所 俊一郎, 稲葉 洋平, 高瀬 圭

    日本放射線技術学会総会学術大会予稿集 72回 267-267 2016/02

    Publisher: (公社)日本放射線技術学会

    ISSN: 1884-7846

  97. 患者被曝測定におけるリアルタイム型MOSFET線量計の基本特性評価

    鈴木 智之, 佐藤 文貴, 本田 崇文, 村上 巧, 千田 浩一, 稲葉 洋平, 芳賀 喜裕, 加賀 勇治

    日本放射線技術学会東北部会雑誌 (25) 201-201 2016/01

    Publisher: (公社)日本放射線技術学会-東北支部

  98. CT装置間におけるCT透視時の空間散乱線分布の比較

    本田 崇文, 佐藤 文貴, 鈴木 智之, 村上 巧, 稲葉 洋平, 千田 浩一, 川畑 朋桂, 森 隆一, 佐久間 政志, 立花 茂, 梁川 功

    日本放射線技術学会東北部会雑誌 (25) 207-207 2016/01

    Publisher: (公社)日本放射線技術学会-東北支部

  99. 血管造影用X線装置間の空間散乱線量の比較

    根本 まなみ, 小林 亮太, 稲葉 洋平, 芳賀 喜裕, 千田 浩一

    日本放射線技術学会雑誌 71 (9) 842-842 2015/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  100. MOSFETリアルタイム線量計の測定精度に関する基礎検討

    佐藤 文貴, 村上 巧, 鈴木 智之, 本田 崇文, 稲葉 洋平, 芳賀 喜裕, 加賀 勇治, 千田 浩一

    日本放射線技術学会雑誌 71 (9) 891-891 2015/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  101. IVR-CT装置のCT透視時における空間散乱線分布の測定

    村上 巧, 本田 崇文, 佐藤 文貴, 鈴木 智之, 稲葉 洋平, 千田 浩一, 立花 茂, 梁川 功

    日本放射線技術学会雑誌 71 (9) 892-892 2015/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  102. 血管造影IVR装置の空間散乱X線量の多施設比較

    松田 拓馬, 三瓶 司, 稲野 理穂, 伊藤 拓未, 小林 亮太, 稲葉 洋平, 千田 浩一

    日本放射線技術学会東北部会雑誌 (24) 163-163 2015/01

    Publisher: (公社)日本放射線技術学会-東北支部

  103. 新しい非接続型X線アナライザの性能評価(第一報)(管電圧測定等に関する検討)

    稲野 理穂, 伊藤 拓未, 三瓶 司, 松田 拓馬, 小林 亮太, 稲葉 洋平, 千田 浩一, 芳賀 善裕, 加賀 勇治

    日本放射線技術学会東北部会雑誌 (24) 198-198 2015/01

    Publisher: (公社)日本放射線技術学会-東北支部

  104. 新しい非接続型X線アナライザの性能評価(第二報)(撮影時間測定やその他の特性に関する検討)

    三瓶 司, 伊藤 拓未, 稲野 理穂, 松田 拓馬, 小林 亮太, 稲葉 洋平, 千田 浩一, 芳賀 善裕, 加賀 勇治

    日本放射線技術学会東北部会雑誌 (24) 199-199 2015/01

    Publisher: (公社)日本放射線技術学会-東北支部

  105. 心血管IVR装置間における線量と画質の関係

    稲葉 洋平, 小林 亮太, 千田 浩一, 梁川 功, 加賀 勇治

    日本放射線技術学会雑誌 70 (9) 986-986 2014/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  106. 新しい非接続形X線測定器の線量測定精度の基礎検討

    伊藤 拓未, 稲野 理穂, 三瓶 司, 松田 拓馬, 小林 亮太, 稲葉 洋平, 千田 浩一

    日本放射線技術学会雑誌 70 (9) 988-988 2014/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  107. 太陽光発電システムを用いた災害時診断用携帯型X線発生装置の開発

    小林 亮太, 稲葉 洋平, 千田 浩一

    日本放射線技術学会雑誌 70 (9) 1062-1062 2014/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  108. 災害時診断用携帯型X線発生装置の試作

    小林 亮太, 稲葉 洋平, 千田 浩一

    日本放射線技術学会総会学術大会予稿集 70回 190-191 2014/02

    Publisher: (公社)日本放射線技術学会

    ISSN: 1884-7846

  109. 多施設の心血管IVR装置における入射線量縦断調査

    稲葉 洋平, 千田 浩一, 小林 亮太, 加賀 勇治, 梁川 功

    日本放射線技術学会総会学術大会予稿集 70回 250-251 2014/02

    Publisher: (公社)日本放射線技術学会

    ISSN: 1884-7846

  110. 医療従事者用リアルタイム被曝測定システムの有用性(第1報)(測定系固有特性)

    稲葉 洋平, 千田 浩一, 小林 亮太, 加賀 勇治, 芳賀 喜裕, 梁川 功

    日本放射線技術学会東北部会雑誌 (23) 172-172 2014/01

    Publisher: (公社)日本放射線技術学会-東北支部

  111. 医療従事者用リアルタイム被曝測定システムの有用性(第2報)(性能比較)

    長島 慎弥, 中村 昌隆, 砂村 あゆみ, 曽田 真宏, 稲葉 洋平, 千田 浩一, 加賀 勇治, 芳賀 喜裕

    日本放射線技術学会東北部会雑誌 (23) 173-173 2014/01

    Publisher: (公社)日本放射線技術学会-東北支部

  112. X線診断領域における新型個人線量計の基礎的評価

    稲葉 洋平, 千田 浩一, 小林 亮太, 梁川 功, 加賀 勇治

    日本放射線技術学会雑誌 69 (9) 1026-1026 2013/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  113. リアルタイム型ポケット線量計の性能比較

    中村 昌隆, 砂村 あゆみ, 曽田 真宏, 長島 慎弥, 稲葉 洋平, 千田 浩一

    日本放射線技術学会雑誌 69 (9) 1026-1026 2013/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  114. コイル感度マップを最適化するicePATを組み込んだTWIST法の画像特性の検討

    佐々木 博信, 大田 英揮, 永坂 竜男, 山中 一臣, 木村 智圭, 稲葉 洋平, 梁川 功

    日本放射線技術学会総会学術大会予稿集 69回 202-202 2013/02

    Publisher: (公社)日本放射線技術学会

    ISSN: 1884-7846

  115. 血管撮影用X線装置における基準点線量の検討 基準点実測線量と装置表示線量の対比

    森島 貴顕, 千葉 浩生, 稲葉 洋平, 田浦 将明, 江端 綾子, 千田 浩一

    日本放射線技術学会雑誌 65 (9) 1306-1306 2009/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  116. 心臓血管IVR用X線装置の散乱X線量の多施設比較

    結城 裕子, 竹川 弥香, 稲葉 洋平, 江端 綾子, 田浦 将明, 舛山 葉菜子, 千田 浩一

    日本放射線技術学会雑誌 64 (9) 1130-1130 2008/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

  117. ワイドダイナミックタイプ新型蛍光量計の性能評価(第35回秋季学術大会放射線防護・管理関連後抄録)

    白鳥 和敏, 佐藤 静, 梁川 功, 千田 浩一, 稲葉 洋平, 江端 綾子, 田浦 将明

    放射線防護分科会会誌 (26) 31-31 2008/04/04

    Publisher: 公益社団法人日本放射線技術学会

    ISSN: 1345-3246

  118. 63rd Annual Scientific Congress of Japanese Society of Radiological Technology : From Student's Angle to the Student

    INABA Yohei

    Japanese journal of radiological technology 63 (9) 1106-1108 2007/09/20

    Publisher: Japanese Society of Radiological Technology (JSRT)

    ISSN: 0369-4305

  119. ワイドダイナミックタイプ新型蛍光量計の性能評価

    白鳥 和敏, 千田 浩一, 佐藤 静, 稲葉 洋平, 江端 綾子, 田浦 将明, 梁川 功

    日本放射線技術学会雑誌 63 (9) 998-998 2007/09

    Publisher: (公社)日本放射線技術学会

    ISSN: 0369-4305

    eISSN: 1881-4883

Show all ︎Show first 5

Presentations 44

  1. ポータブル撮影における空間散乱線量評価に関する基礎検討

    大友 一輝, 有馬 悠貴, 齊藤 新, 芳賀 喜裕, 阿部 美津也, 加賀 勇治, 稲葉 洋平, 千田 浩一

    日本放射線技術学会雑誌 2018/09

  2. 診断領域エネルギにおける水晶体職業被ばく測定用線量計の基本特性評価 安定性およびFadingに関する検討

    田辺 ゆうき, 田母神 陽, 菅原 拓巳, 石井 浩生, 芳賀 喜裕, 稲葉 洋平, 加賀 勇治, 千田 浩一

    日本放射線技術学会雑誌 2018/09

  3. 空間散乱X線のエネルギー測定による放射線防護眼鏡の鉛当量厚の検討

    薩來 康, 石井 浩生, 芳賀 喜裕, 加賀 勇治, 佐藤 文貴, 本田 崇文, 稲葉 洋平, 千田 浩一

    日本放射線技術学会雑誌 2018/09

  4. IVRに従事するスタッフの水晶体線量計着用部位に関する基礎検討

    石井 浩生, 薩來 康, 芳賀 喜裕, 加賀 勇治, 阿部 美津也, 稲葉 洋平, 千田 浩一

    日本放射線技術学会雑誌 2018/09

  5. MRIの設置および利用状況調査

    佐藤 美帆, 別所 俊一郎, 稲葉 洋平, 町田 好男, 高瀬 圭

    日本放射線技術学会雑誌 2018/09

  6. Usefulness of Novel Radiation Dosimeter Using a Multi-channel Real-time Monitor

    Inaba Yohei, Ishii Hiroki, Satsurai Ko, Haga Yoshihiro, Chida Koichi

    日本放射線技術学会総会学術大会予稿集 2018/03

  7. 電子スピン共鳴法を用いた被ばく後の酸化ストレスレベルの測定

    孫 略, 稲葉 洋平, 佐藤 圭創, 平山 暁, 坪井 康次, 千田 浩一, 盛武 敬

    日本放射線影響学会大会講演要旨集 2017/10

  8. 新型半導体式サーベイメータの基礎検討 散乱X線平均エネルギー測定精度の検討

    薩來 康, 石井 浩生, 佐藤 文貴, 本田 崇文, 稲葉 洋平, 千田 浩一, 宮田 恒平, 三戸 麻莉菜

    日本放射線技術学会雑誌 2017/09

  9. IVR装置における患者照射基準点線量の測定及び線量表示値との比較

    本田 崇文, 佐藤 文貴, 石井 浩生, 薩來 康, 稲葉 洋平, 立花 茂, 加賀 勇治, 千田 浩一

    日本放射線技術学会雑誌 2017/09

  10. PCI及びPercutaneous Peripheral Intervention(PPI)に従事する医師における水晶体被ばく線量の左右差についての初期的検討

    佐藤 文貴, 本田 崇文, 芳賀 喜裕, 石井 浩生, 薩來 康, 稲葉 洋平, 加賀 勇治, 千田 浩一

    日本放射線技術学会雑誌 2017/09

  11. IVR装置間における患者照射基準点線量測定から見えてきた実測の重要性

    稲葉 洋平, 本田 崇文, 佐藤 文貴, 芳賀 喜裕, 千田 浩一

    IVR: Interventional Radiology 2017/04

  12. Fundamental Study of a Novel Radiation Dosimeter Using a Multi-Channel Real-Time Monitor

    Inaba Yohei, Honda Takfumi, Sato Fumitaka, Chida Koichi, Haga Yoshihiro, Kaga Yuji

    日本放射線技術学会総会学術大会予稿集 2017/03

  13. 英語発表のポイントとコツ 若手会員に向けるメッセージ

    稲葉 洋平

    日本放射線技術学会総会学術大会予稿集 2017/03

  14. CT透視下生検における術者被曝線量計の位置に関する検討

    本田 崇文, 佐藤 文貴, 稲葉 洋平, 千田 浩一, 常陸 真

    日本放射線技術学会東北部会雑誌 2017/01

  15. 血管造影・IVRに従事する医師、看護師の被曝線量の検討

    佐藤 文貴, 稲葉 洋平, 千田 浩一, 本田 崇文, 片岡 望, 熊坂 江里子, 芳賀 喜裕, 阿部 美津也, 加賀 勇治

    日本放射線技術学会東北部会雑誌 2017/01

  16. 新型半導体式サーベイメータの基本特性評価

    宮田 恒平, 石井 浩生, 三戸 麻莉菜, 加藤 槙子, 上杉 直人, 千田 浩一, 稲葉 洋平, 本田 崇文, 佐藤 文貴, 斎 政博, 加賀 勇治, 芳賀 喜裕

    日本放射線技術学会東北部会雑誌 2017/01

  17. 心血管IVR装置間における患者照射基準点線量の実測と線量表示値の比較

    上杉 直人, 石井 浩生, 宮田 恒平, 加藤 槙子, 三戸 麻莉菜, 稲葉 洋平, 千田 浩一

    日本放射線技術学会東北部会雑誌 2017/01

  18. X線CT透視時のX線CT装置間での空間散乱線分布の比較 ファントム実験

    本田 崇文, 稲葉 洋平, 千田 浩一, 川畑 朋桂, 森 隆一, 佐藤 文貴, 立花 茂, 梁川 功

    日本放射線技術学会雑誌 2016/09

  19. センサーの違いによるリアルタイム型MOSFET線量計の基本特性評価

    佐藤 文貴, 千田 浩一, 稲葉 洋平, 本田 崇文, 芳賀 喜裕, 加賀 勇治, 上杉 直人

    日本放射線技術学会雑誌 2016/09

  20. 半導体センサを使用した新しいサーベイメータの基礎検討

    石井 浩生, 宮田 恒平, 三戸 麻莉菜, 加藤 槙子, 佐藤 文貴, 本田 崇文, 稲葉 洋平, 千田 浩一

    日本放射線技術学会雑誌 2016/09

  21. CT透視下生検における従事者被曝線量の実測

    稲葉 洋平, 千田 浩一, 常陸 真, 綿貫 宗則

    IVR: Interventional Radiology 2016/04

  22. MRIの保有状況と利用に関する全国調査

    佐藤 美帆, 町田 好男, 別所 俊一郎, 稲葉 洋平, 高瀬 圭

    日本放射線技術学会総会学術大会予稿集 2016/02

  23. 多施設心血管IVR装置における患者照射基準点線量の実測 DRLs2015との考察

    稲葉 洋平, 千田 浩一, 小林 亮太, 梁川 功, 加賀 勇治

    日本放射線技術学会総会学術大会予稿集 2016/02

  24. CT装置間におけるCT透視時の空間散乱線分布の比較

    本田 崇文, 佐藤 文貴, 鈴木 智之, 村上 巧, 稲葉 洋平, 千田 浩一, 川畑 朋桂, 森 隆一, 佐久間 政志, 立花 茂, 梁川 功

    日本放射線技術学会東北部会雑誌 2016/01

  25. 患者被曝測定におけるリアルタイム型MOSFET線量計の基本特性評価

    鈴木 智之, 佐藤 文貴, 本田 崇文, 村上 巧, 千田 浩一, 稲葉 洋平, 芳賀 喜裕, 加賀 勇治

    日本放射線技術学会東北部会雑誌 2016/01

  26. IVR-CT装置のCT透視時における空間散乱線分布の測定

    村上 巧, 本田 崇文, 佐藤 文貴, 鈴木 智之, 稲葉 洋平, 千田 浩一, 立花 茂, 梁川 功

    日本放射線技術学会雑誌 2015/09

  27. MOSFETリアルタイム線量計の測定精度に関する基礎検討

    佐藤 文貴, 村上 巧, 鈴木 智之, 本田 崇文, 稲葉 洋平, 芳賀 喜裕, 加賀 勇治, 千田 浩一

    日本放射線技術学会雑誌 2015/09

  28. 血管造影用X線装置間の空間散乱線量の比較

    根本 まなみ, 小林 亮太, 稲葉 洋平, 芳賀 喜裕, 千田 浩一

    日本放射線技術学会雑誌 2015/09

  29. 新しい非接続型X線アナライザの性能評価(第二報)(撮影時間測定やその他の特性に関する検討)

    三瓶 司, 伊藤 拓未, 稲野 理穂, 松田 拓馬, 小林 亮太, 稲葉 洋平, 千田 浩一, 芳賀 善裕, 加賀 勇治

    日本放射線技術学会東北部会雑誌 2015/01

  30. 新しい非接続型X線アナライザの性能評価(第一報)(管電圧測定等に関する検討)

    稲野 理穂, 伊藤 拓未, 三瓶 司, 松田 拓馬, 小林 亮太, 稲葉 洋平, 千田 浩一, 芳賀 善裕, 加賀 勇治

    日本放射線技術学会東北部会雑誌 2015/01

  31. 血管造影IVR装置の空間散乱X線量の多施設比較

    松田 拓馬, 三瓶 司, 稲野 理穂, 伊藤 拓未, 小林 亮太, 稲葉 洋平, 千田 浩一

    日本放射線技術学会東北部会雑誌 2015/01

  32. 太陽光発電システムを用いた災害時診断用携帯型X線発生装置の開発

    小林 亮太, 稲葉 洋平, 千田 浩一

    日本放射線技術学会雑誌 2014/09

  33. 新しい非接続形X線測定器の線量測定精度の基礎検討

    伊藤 拓未, 稲野 理穂, 三瓶 司, 松田 拓馬, 小林 亮太, 稲葉 洋平, 千田 浩一

    日本放射線技術学会雑誌 2014/09

  34. 心血管IVR装置間における線量と画質の関係

    稲葉 洋平, 小林 亮太, 千田 浩一, 梁川 功, 加賀 勇治

    日本放射線技術学会雑誌 2014/09

  35. 多施設の心血管IVR装置における入射線量縦断調査

    稲葉 洋平, 千田 浩一, 小林 亮太, 加賀 勇治, 梁川 功

    日本放射線技術学会総会学術大会予稿集 2014/02

  36. 災害時診断用携帯型X線発生装置の試作

    小林 亮太, 稲葉 洋平, 千田 浩一

    日本放射線技術学会総会学術大会予稿集 2014/02

  37. 医療従事者用リアルタイム被曝測定システムの有用性(第2報)(性能比較)

    長島 慎弥, 中村 昌隆, 砂村 あゆみ, 曽田 真宏, 稲葉 洋平, 千田 浩一, 加賀 勇治, 芳賀 喜裕

    日本放射線技術学会東北部会雑誌 2014/01

  38. 医療従事者用リアルタイム被曝測定システムの有用性(第1報)(測定系固有特性)

    稲葉 洋平, 千田 浩一, 小林 亮太, 加賀 勇治, 芳賀 喜裕, 梁川 功

    日本放射線技術学会東北部会雑誌 2014/01

  39. リアルタイム型ポケット線量計の性能比較

    中村 昌隆, 砂村 あゆみ, 曽田 真宏, 長島 慎弥, 稲葉 洋平, 千田 浩一

    日本放射線技術学会雑誌 2013/09

  40. X線診断領域における新型個人線量計の基礎的評価

    稲葉 洋平, 千田 浩一, 小林 亮太, 梁川 功, 加賀 勇治

    日本放射線技術学会雑誌 2013/09

  41. コイル感度マップを最適化するicePATを組み込んだTWIST法の画像特性の検討

    佐々木 博信, 大田 英揮, 永坂 竜男, 山中 一臣, 木村 智圭, 稲葉 洋平, 梁川 功

    日本放射線技術学会総会学術大会予稿集 2013/02

  42. 血管撮影用X線装置における基準点線量の検討 基準点実測線量と装置表示線量の対比

    森島 貴顕, 千葉 浩生, 稲葉 洋平, 田浦 将明, 江端 綾子, 千田 浩一

    日本放射線技術学会雑誌 2009/09

  43. 心臓血管IVR用X線装置の散乱X線量の多施設比較

    結城 裕子, 竹川 弥香, 稲葉 洋平, 江端 綾子, 田浦 将明, 舛山 葉菜子, 千田 浩一

    日本放射線技術学会雑誌 2008/09

  44. ワイドダイナミックタイプ新型蛍光量計の性能評価

    白鳥 和敏, 千田 浩一, 佐藤 静, 稲葉 洋平, 江端 綾子, 田浦 将明, 梁川 功

    日本放射線技術学会雑誌 2007/09

Show all Show first 5

Industrial Property Rights 3

  1. 電源システム及び医用X線システム

    千田 浩一, 小林 亮太, 稲葉 洋平, 佐藤 公悦, 伊与木 勉

    特許第6488455号

    Property Type: Patent

  2. 放射線被ばくによる皮膚炎発生の予測

    孫 略, 盛武 敬, 千田 浩一, 稲葉 洋平

    Property Type: Patent

  3. 電源システム及び医用X線システム

    千田 浩一, 小林 亮太, 稲葉 洋平, 佐藤 公悦, 伊与木 勉

    Property Type: Patent

Research Projects 9

  1. 放射線計測と被曝防護を同時に実現するハイブリット型線量計デバイスの開発

    稲葉 洋平

    Offer Organization: 日本学術振興会

    System: 科学研究費助成事業 基盤研究(C)

    Category: 基盤研究(C)

    Institution: 東北大学

    2023/04/01 - 2026/03/31

  2. 放射線従事者に資する持続可能な放射線被曝防護システムの開発

    常陸 真, 稲葉 洋平

    Offer Organization: 日本学術振興会

    System: 科学研究費助成事業

    Category: 基盤研究(C)

    Institution: 東北大学

    2021/04/01 - 2024/03/31

    More details Close

    放射線業務は、一般撮影(X線ポータブル撮影含む)・CT (Computed Tomography) ・IVR (Interventional Radiology) ・核医学検査・放射線治療など多岐にわたる。また、あらゆる職種が放射線を駆使しながらチーム医療で展開するために、放射線教育を十分に受けていない放射線医療従事者が水晶体被曝をする可能性が想定される。そこで本研究課題では、様々な放射線検査に資する医療従事者があらゆる場面で持続可能な水晶体防護策を瞬時に対応するためのモバイル型水晶体被曝防護システムの開発を試みる。これまで我々の研究グループは、基盤研究Cにおいて可搬型の水晶体防護機器の開発を行い、臨床使用時で約50%の従事者被曝低減を実現している。既存のノウハウを駆使し、移動性に特化させたあらゆる場面で持続可能なモバイル型放射線防護機器の実現を目指す。 2021年度は、さまざまな放射線検査場(CT透視下インターベンション、一般撮影、ポータブル撮影、歯科撮影領域)における平面および高さ双方の空間散乱線量分布の測定を行い、3次元的な基礎データを得た(新型コロナウィルス感染症の影響で当初予定していた他モダリティーの測定は行えなかった)。これらの空間散乱線分布を基盤に次年度に向けたプロトタイプのモバイル型放射線防護機器の開発を検討する。具体的には、防護板の形状や鉛当量、モバイル形状についての検討を行う。

  3. 水晶体被曝を可視化する医療用ウェアラブル防護デバイスの開発

    稲葉 洋平, 千田 浩一, 常陸 真, 加田 渉

    Offer Organization: 日本学術振興会

    System: 科学研究費助成事業

    Category: 基盤研究(C)

    Institution: 東北大学

    2019/04/01 - 2023/03/31

    More details Close

    放射線医療従事者の業務は、一般撮影(X線ポータブル撮影含む)・CT (Computed Tomography) ・IVR (Interventional Radiology) ・核医学 検査・放射線治療など多岐にわたる。2011年に国際放射線防護委員会 (ICRP) は、水晶体等価線量限度を今まで考えられてきたものより約1/8に引き下げる勧告(150 mSv/year → 20 mSv/year)をしたため、放射線従事者が放射線白内障になる危険性が大幅に増加することが危惧されており、可及的速やかな対応が国際的な課題となっている。ゆえにあらゆる医療従事者に水晶体防護策を施行するためには水晶体被曝を可視化して放射線防護教育することが今後の法改正に 向けて必要であるが水晶体防護と教育を併せ持つ医療用デバイスが存在しない。本研究では水晶体被曝を可視化できる医療用ウェアラブル型水晶体防護メガネの開発を試みる。 2019年度は、様々な放射線検査場の中で歯科領域、CT領域の平面および高さ双方の空間散乱線量分布の測定を行い、水晶体高さレベルでの3次元的な空間散乱線量の基礎データを得ることができた。また、実際に歯科X線装置およびCTガイド下インターベンションに従事するスタッフの被ばく線量測定を一部開始した。2020年度は、CT透視下インターベンション時の医師、看護師の放射線被曝測定を実施した(Inaba. Y, Diagnostics 2021)。2021年度は、ラジオフォトルミネセンス現象を用いて水晶体被曝を可視化できる眼鏡型の線量計デバイスを作成した。線量依存的にデバイス光量が増加することを確認した。さらには、当該デバイスが水晶体防護効果50%程度あることも確認した。

  4. 医療従事者や介助者に資する多機能型水晶体被曝防護機器の開発

    常陸 真, 稲葉 洋平

    Offer Organization: 日本学術振興会

    System: 科学研究費助成事業

    Category: 基盤研究(C)

    Institution: 東北大学

    2018/04/01 - 2023/03/31

    More details Close

    放射線業務従事者が個人線量計を使用している人数は約50万人である。その内、現行法令の水晶体被曝線量限度 (150 mSv/year) を超えているのは約10人たらずである。しかし、2011年に国際放射線防護委員会 (ICRP) は、水晶体等価線量限度を約1/8に引き下げる勧告 (20 mSv/year) をしたため、放射線業務従事者が放射線白内障になる危険性が危惧されており、可及的速やかな対応が国際的な課題となっている。この新勧告に当てはめると、我が国の平成26年度の実績から約2500人が該当する。ゆえに現行の線量限度に比べ250倍の人が線量限度超過の可能性があり、可及的速やかな対応と備えが今後の法改正に向けて必要であるが、移動性と多様性に優れた適切な水晶体防護機器が存在しないのが現状である。本研究では、放射線業務従事者および介助者まで対応可能なさまざまな放射線検査に資する水晶体被曝防護機器の開発を試みる。 初年度は、放射線検査(特にCT透視下インターベンション)時の平面および高さ双方の空間散乱線量分布の測定を行った。水晶体高さレベルでの3次元的な空間散乱線量の基礎データを得ることができた。実験場所は、主に在籍する東北大学医学部保健学科の一般撮影室、CT室、そして東北大学病院臨床CT装置で行った。また、空間散乱線量分布を参考に医療従事者のどの位置に線量計を配置するかの検討を重ねた。

  5. Installation and utilization situation of MRI in Japan

    Sato Miho, TAKASE Kei, INABA Yohei, MORI Naoko, NAGASAKA Tatsuo, HIKICHI Takeo

    Offer Organization: Japan Society for the Promotion of Science

    System: Grants-in-Aid for Scientific Research

    Category: Grant-in-Aid for Scientific Research (C)

    Institution: Tohoku University

    2015/04/01 - 2018/03/31

    More details Close

    Even though it is frequently cited that Japan has the highest number of MRIs per person, we rarely find studies evaluated those utilities and installations. This study aims to survey MRI installation and utilities in Japan. We mailed questionnaire to 5,437 facilities have MRI(s) and we received 2,272 responses (41.8% response rate). Questions include the type of facility, the detail information about their installed MRI, and their utilization such as operation rate per day, target of scans, scan protocol, staffing, etc. From a statistical analysis of the collected data, many of the clinics and the hospitals with a small number of beds did not have a full-time radiologist or a radiographer. This data will be effective for future discussion of MRI installation in Japan.

  6. Development of a new nontoxic dosimeter for real-time measurements of patient radiation doses

    ZUGUCHI MASAYUKI, YAMADA Shogo, CHIDA Koichi, NAKAMURA Masaaki, KATO Mamoru, INABA Yohei

    Offer Organization: Japan Society for the Promotion of Science

    System: Grants-in-Aid for Scientific Research

    Category: Grant-in-Aid for Scientific Research (C)

    Institution: Tohoku University

    2014/04/01 - 2017/03/31

    More details Close

    There are no effective real-time direct skin dosimeters for interventional radiology (IVR). Therefore, we produced a prototype of a real-time dosimeter for patients undergoing IVR that uses a nontoxic phosphor. The basic characteristics of the real-time dosimeter prototype are comparable to those of the previously used skin dose monitor (SDM), with the exception that our prototype has the distinct advantage of including multichannel sensors. The novel dosimeter exhibited equivalent performance with respect to energy dependence and linearity, etc., compared with an SDM. To date, no feasible method exists for measuring the radiation dose to the patient in real-time during IVR. Therefore, the novel real-time dosimeter system is expected to useful in measuring patients’ exposure dose during IVR.

  7. Improvement of patient dose management: Development of a patient radiation dose evaluation system

    CHIDA Koichi, MORITAKE Takashi, ZUGUCHI Masayuki, KATO Mamoru, TANO Masakatsu, NAKAMURA MasaAaki, DENDOU Yutaka, INABA Yohei

    Offer Organization: Japan Society for the Promotion of Science

    System: Grants-in-Aid for Scientific Research

    Category: Grant-in-Aid for Scientific Research (B)

    Institution: Tohoku University

    2012/04/01 - 2016/03/31

    More details Close

    Patient dose management using DICOM header files is becoming common. However, some problems have become apparent, because dose information may be stored in ‘private’ fields in many instances and dose units vary among manufacturers. Furthermore, it is not uncommon to find that a DICOM header file has no dose information. Therefore, it is imperative to standardize DICOM header dose information. Some recent reports have described the usefulness of patient dose management using DICOM SR. However, the use of DICOM SRs in X-ray systems is currently very limited. We have developed a dose-management system using an RIS and an MPPS interface. Both radiographic information from the X-ray system and dosimetric information from the DAP meter can be sent to the RIS using the MPPS interface. To improve dose management, it is necessary to use a combination of DICOM and an RIS system.

  8. Fundamental study of a Real-time Dosimeter using a Diagnostic X-rayApparatus for Interventional Radiology

    ZUGUCHI Masayuki, CHIDA Koichi, NAKAMURA Masaaki, KATO Mamoru, INABA Yohei

    Offer Organization: Japan Society for the Promotion of Science

    System: Grants-in-Aid for Scientific Research

    Category: Grant-in-Aid for Scientific Research (C)

    Institution: Tohoku University

    2010 - 2012

    More details Close

    Radiation protection is an important issue in interventional radiology (IVR) for which the radiation dose should be monitored. To protect against patient skin injury, the radiation dose should be monitored in real-time. When more than one effective working view is available, a combination of different viewing angles and real-time monitoring of patient dose can be used to prevent any one skin area from receiving excessive radiation, thereby reducing the risk of skin injury. However, no feasible real-time patient dose measuring method has been established. The purpose of this study was to evaluate the feasibility of using real-time dosimeter to measure patient skin exposure dose after exposure to diagnostic X-ray energies during IVR. The real-time dosimeter detector consists of x-ray scintillator, optical fiber and photodiode. The real-time dosimeter was not visible on X-ray images at diagnostic energies. Furthermore, the real-time dosimeter is easy to handle. Therefore, it will be feasible to use the real-time dosimeter at diagnostic X-ray energies for measuring patient dose during IVR.

  9. PROTECTIVE APRON FOR IVR PHYSICIANS

    ZUGUCHI Masayuki, CHIDA Koichi, YAMADA Shogo, CHIDA Koichi, YAMADA Shogo, NAKAMURA Masaaki, SATO Tadaya, KATO Kato, INABA Inaba, TAURA Masaaki

    Offer Organization: Japan Society for the Promotion of Science

    System: Grants-in-Aid for Scientific Research

    Category: Grant-in-Aid for Scientific Research (C)

    Institution: Tohoku University

    2007 - 2008

Show all Show first 5